![Energie MONOBLOC 100esm Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/energie/monobloc-100esm/monobloc-100esm_technical-manual_2409992041.webp)
41
MONOBLOC 100L
English
Adjust the hut in the back of the equipment so you can assure the minimum tilt of 1 degree backwards.
If equipment tilts other than back-
wards, this will cause condensates
to deposit in the tank.
4.3. Air Inlet/Outlet Installation
4.3.1. Installation Without Ducts
The AquaPura Monobloc equipment must be installed in a place that is not too heated, and may be used
for dehumidifying and cooling these rooms (e.g., laundries, cellars, etc).
Distance between the top of the unit and the ceiling must be no less than 600mm (figura A).
As the AquaPura Monobloc absorbs heat during its operation, the air flow (inlet/out
-
let) must be directed to unheated areas. The equipment will cool the room where it is
placed and so if it is installed in heater rooms, the air flow must be directed to other
rooms and/or the outside.
If the distance between the unit and the ceiling is less than 600mm, two elbow-type joints must be in-
stalled as shown in the following picture (B/ C).
WARNING
Technical Manual
Содержание MONOBLOC 100esm
Страница 2: ......
Страница 4: ...4 MONOBLOC 100L Manual T cnico Portugu s...
Страница 30: ...30 MONOBLOC 100L Manual T cnico...
Страница 32: ...32 MONOBLOC 100L English Technical Manual...
Страница 58: ...58 MONOBLOC 100L...
Страница 60: ...60 MONOBLOC 100L Espa ol Manual T cnico...
Страница 86: ...Notas Notes Notas...
Страница 87: ...Notas Notes Notas...
Страница 88: ...Notas Notes Notas...
Страница 89: ...Notas Notes Notas...
Страница 90: ...Notas Notes Notas...
Страница 91: ......