4. Thermostat Wiring
The following diagram shows the backplate of the Energate thermostat.
Conventional System
The following are the general wiring connections for a conventional system.
Conventional Systems (CONV)
1
Common(GND)
C
8
2
Power (24VAC)
R
9
3
RS OUT
Outdoor Sensor
1st Stage Heat
W1
10
4
RS GND
Sensor Ground
Fan
G
11
5
FILTER
Filter
1st Stage Cool
Y1
12
6
2nd Stage Cool
Y2
13
7
2nd Stage Heat
W2
14
Heat Pump
The following are the general wiring connections for a heat pump.
Heat Pump Systems (HP)
1
Common (GND)
C
8
2
FAULT
Heat Pump Fault
Power (24VAC)
R
9
3
RS OUT
Outdoor Sensor
Auxiliary Heat
E
10
4
RS GND
Sensor Ground
Fan
G
11
5
FILTER
Filter
1st Stage Heat Pump
Y1
12
6
2nd Stage Heat Pump
Y2
13
7
Reversing Valve
*
O/B
14