3. No Existing Thermostat
Mounting the Thermostat
Install the thermostat at 5 feet (1.5m) above the floor in an area with good air circulation at
average temperature. Avoid locations with drafts or dead spots behind doors, hot or cold air
ducts, sunlight or radiant heat from appliances, concealed pipes or chimneys and unconditioned
areas such as outside walls behind the thermostat.
The 2 wallplate anchors should be spaced 3.5 inches (90 mm) apart in a vertical direction. Pull
wires through the backplate and connect to the appropriate terminals as defined in the Wiring
Configuration.
Mounting the Outdoor Sensor
The outdoor sensor should be mounted in a shaded location, out of direct sunlight. The
thermostat will automatically detect the outdoor sensor and display its readings.
Cleaning the Thermostat
The thermostat can be cleaned with a soft cloth
lightly dampened
with isopropyl alcohol
(IPA)
.
Excessive IPA or use of other solvents may damage the LCD!
Removing Thermostat Front Housing from Backplate
To remove the thermostat front housing from the backplate, press the plastic tab located at the
bottom of the thermostat. Pull the bottom of the front housing forward and remove.
Warning:
do not use metallic tools
when removing battery or backplate; this may damage the
thermostat.