6.6 Display Properties
These Functions can be used to personalize the normal operating mode. You can choose to skip
viewing parameters in the bottom display row that you are not interested in. The State of Charge
value shown in the upper parameter row cannot be skipped.
F9.0
Show voltage.
Default: ON
Range: OFF / ON
F9.1
Show current.
Default: ON
Range: OFF / ON
F9.2
Show power.
Default: OFF
Range: OFF / ON
F9.3
Show Amp-hours.
Default: OFF
Range: OFF / ON
F9.4
Show time remaining.
Default: ON
Range: OFF / ON
F9.5
Show temperature.
Default: ON
Range: OFF / ON
F9.7
Show bank 2 voltage. Only available when F2.0 is set to AUX.BAT.
Default: ON
Range: OFF / ON
F9.8
Show bank 3 voltage. Only available when F3.0 is set to AUX.BAT.
Default: ON
Range: OFF / ON
F9.9
Auto hide parameter. The default setting will allow the bottom parameter to only
show for 120 seconds after the ePRO Plus has been accessed. This will keep the
display clean under normal conditions, which might be preferred by less technical
end users. When auto hide is set to OFF, the bottom parameter row is always visible.
Default: 120sec
Range: OFF / 5 – 300sec