![Enerdrive ePro Plus Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/enerdrive/epro-plus/epro-plus_owners-manual_2409561020.webp)
Enerdrive ePRO Plus Battery Monitor Owners Manual (Rev. 1.03)
Page 20
F1.1
Battery capacity. Your Main battery’s capacity in Amphours (Ah).
Default: 200Ah
Range: 10 – 10000Ah
Step size: variable
F1.2
Nominal discharge rate (C-rating). The discharge rate (in hours) at which the battery
manufacturer rates your battery’s capacity.
Default: 20h
Range: 1 – 20h
Step size: 1h
F1.3
Nominal temperature. The temperature at which the battery manufacturer rates
your battery’s capacity.
Default: 20°C
Range: 0 – 40°C
Step size: 1°C
F1.4
Peukert’s exponent. Peukert’s exponent represents the e ect of reducing battery
capacity at higher discharge rates. When the Peukert value of your battery is unknown,
it is recommended to keep this value at 1.17. A value of 1.00 disables the Peukert
compensation and should be used for Lithium based batteries.
Default: 1.17
Range: 1.00 – 1.50
Step size: 0.01
F1.5
Reserved.
Default: -
Range: -
Step size: -
F1.6
Battery temperature. In this Function the average battery temperature can be adjusted
when no temperature sensor is connected. When a temperature sensor is connected,
the temperature readout in the Normal Operating Mode is enabled.
Default: 20°C
Range: -20°C – 50°C
Step size: 1°C
F1.7
Battery bank 1 name. Choose a display name for your battery bank that comes nearest
to your application.
Default: MAIN
Range: see table 8
Table 8
Battery bank name
Description
Bank 1
Battery bank 1
Bank 2
Battery bank 2
Bank 3
Battery bank 3
Main
Main battery bank