4.2 LOAD WORKING MODES
1) DISPLAY AND OPERATION
2) LOAD WORKING MODE
When the LCD shows the above interface, operate as following:
Step 1:
Press the button and hold for 5s to enter the load mode interface.
Step 2:
Press the button when the load mode interface is flashing.
Step 3:
Press the button to confirm the load working modes.
1**
100
Light ON/OFF. Must be 101-115 to use 2N
function.
Load will be on for 1 hour after sunset
Load will be on for 2 hours after sunset
Load will be on for 3 ~ 13 hours after sunset
Load will be on for 14 hours after sunset
Load will be on for 15 hours after sunset
Test mode
Manual mode (default load ON)
2n
201
202
203
~213
Disabled
Disabled
Disabled
Load will be on for 1 hour before sunrise
Load will be on for 2 hours before sunrise
Load will be on for 3 ~ 13 hours before sunrise
Load will be on for 14 hours before sunrise
Load will be on for 15 hours before sunrise
101
102
114
214
215
2 n
2 n
115
117
116
103
~113
Timer 1 - After Sunset
Timer 2 - Before Sunrise
2**
TECHNICAL INFORMATION
Please set Light ON/OFF, Test mode and Manual mode via Timer1. Timer2 will be disabled and display "2 n”.