Connect the remote temperature sensor cable to the solar controller and place the other end close to the
battery/batteries being charged.
Step 4: Connect Accessories
Step 5
:
Powering the controller
•
If the batteries being charged are in a different location to the solar controller it is recommended to use
the remote temperature sensor.
Controller Mounted
Temperature Sensor
Remote
Temperature Sensor
If the remote temperature sensor is not connected to the controller, the default setting for battery
charging or discharging temperature is 25 °C without temperature compensation.
Closing the battery fuse/circuit breaker will switch on the controller. Then check the status of the battery
indicator (the controller is operating normally when the indicator is lit in green). Close the fuse and circuit
breaker of the load and PV array. Then the system will be operating in the preprogrammed mode.
NOTE
If the controller is not operating properly or the battery indicator on the controller shows an
abnormality, please refer to 5.2 “Troubleshooting” (page 24 & 25).