TROUBLESHOOTING

TROUBLE

CAUSE

SOLUTION

Heater does not start

•No power 

•Check main distribution board and power supply line 

•Faulty cable/connections

•Check/have cable replaced by a qualified electrician

•Burnt fuse 

•Check and replace if required

•Room thermostat set too low

•Set room thermostat on a higher temperature

•Thermostat socket cap not inserted

•Insert cap into the thermostat socket

•The safety thermostat has been activated 

•Reset  the  safety  thermostat

Heater starts, flame ignites

•Dirty or faulty flame sensor 

•Clean or replace

but then heater locks out

•Faulty burner control unit 

•Contact service personnel

Heater starts, flame does

•Clogged nozzle

•Clean or replace

not ignite and then heater

•Flame sensor receives an external

•Check for external lights (sun, lamps, etc.)

locks out

light signal during ignition sequence

 

•Faulty burner control unit

•Contact service personnel

•No fuel

•Fill tank

•Ignition fault, dirty or incorrectly

•Clean electrodes, contact service personnel if required

spaced electrodes 

Heater starts, but

•Dirty or blocked nozzle

•Clean or replace

combustion is not good 

•Clogged filters

•Clean or replace

•Leakes in fuel circuit

•Check and eventually replace

•Oil pump provides low pressure

•Contact service personnel

•Insufficient combustion air

•Wrong air lock setting 

•Insufficient ventilation air

•Contact service personnel

Heater stops due to safety

thermostat 

•The appliance has overheated

•Contact service personnel

•Faulty safety thermostat

•Contact service personnel

WIRING DIAGRAM

Содержание HeatStar HS180ID

Страница 1: ...44135 216 881 5500 INDIRECT FIRED PORTABLE HEATER If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life WARN...

Страница 2: ...ERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER WARNING NOT FOR HO...

Страница 3: ...MODEL 180 300 Thermal power BTU hr 181 000 289 000 Air Flow Rating ft min 1475 2650 Oil Consumption gal hr 1 29 2 06 Fuel Nozzle 1 00 60 H 1 50 80 W Efficiency 87 1 88 5 Noise Level at 2m dB A 73 73...

Страница 4: ...contact with the combustion chamber that can be reached through the inspection cover To reset the thermostat unplug the heater open the inspection cover and push the reset button on the thermostat bo...

Страница 5: ...ce personnel Heater starts flame does Clogged nozzle Clean or replace not ignite and then heater Flame sensor receives an external Check for external lights sun lamps etc locks out light signal during...

Страница 6: ...eater Operating Instructions and Owner s Manual EV Fuel Solenoid Valve TR Ignition Transformer M Motor SL Warning Lamp TS Safety Thermostat FS Fuse FC Flame Sensor PL Reset Button IN Switch TH Room Th...

Страница 7: ...7 Operating Instructions and Owner s Manual ENERCO GROUP INC Indirect Fired Portable Heater THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 8: ...hip If a part is damaged or missing call our Technical Support Department at 800 251 0001 Address any Warranty Claims to the Service Department Enerco Group Inc 4560 W 160TH ST Cleveland Ohio 44135 In...

Отзывы: