Operating Instructions and Owner’s Manual

ENERCO GROUP, INC. |Indirect Fired Portable Heater

APPLIANCE DESCRIPTION

Mobile space heater with:

closed combustion chamber and gas exhaust duct (indirect-
fired models)

open combustion chamber (direct-fired models)

INSTALLATION INSTRUCTIONS

General instructions

The heater must be operated only by properly trained

personnel. The manufacturer’s instructions must be followed.

The heater must be installed and operated so that people are

not exposed to dangers deriving from exhaust gases, from the hot
air flow and in such a way that no fire risks exist.

It is forbidden to install the heater in the surroundings of

flammable materials, combustible products, or in places where
explosion risk exist.

When the heater is used in a closed room, ensure a minimum

volume of 28,300 ft³ for the HS180ID model and 53,000 ft³ for the
HS300ID model and a continuous natural air circulation through
windows and doors. For a good combustion, provide approximately
47 cfm air flow from outside.

For the use of the heater the general and special  fire safety

regulations in force in all fields of applications must be followed. In
any case the following minimum safety clearances from materials
or objects in the surroundings of the heater must be ensured:

SPECIFICATIONS

MODEL # .............................. 180 ..................... 300

Thermal power (BTU/hr) ........ 181,000  ............... 289,000 

Air Flow Rating (ft³/min) ....... 1475 .................... 2650

Oil Consumption (gal/hr) ....... 1.29 ..................... 2.06

Fuel Nozzle ............................. 1.00 60° H ........... 1.50 80° W

Efficiency (%) ........................ 87.1 ..................... 88.5

Noise Level at 2m (dB(A)) ...... 73 ....................... 73

Voltage (V) ............................ 110V 60Hz 1ph .... 110V 60Hz 1ph

Electrical Power (W) ............... 460 ..................... 800

Current Rating (A) ................. 7.0 ....................... 12.0

Weight (lb) ............................. 167 ...................... 267

Length  (in) ............................ 55 ........................ 66

Width (in) ............................... 24 ........................ 27

Height (in) .............................. 31 ........................ 37

Flue Diameter (in) .................. 6 ......................... 6

Tank Capacity (gal) ................ 14 ........................ 26

Fuel Pressure (psi) .................. 175 ...................... 175

Air Lock Setting  ..................... 2 ......................... 5.5

Clearances:

Sides: 2.5 ft

Air inlet:

2.5 ft

Top:

6 ft

Air outlet: 12 ft

Floors and ceilings must be made of fireproof materials in the

room where the heater is operated.

The air inlet and outlet must never be blocked for any reason.

Install the heater on a flat, level floor in a steady position.

It is forbidden to connect direct-fired heaters to air ducts.

Maintenance and checks

Depending on the operational conditions, usually every year,

the heater should be checked by qualified personnel.

Prior to start-up, the user must check for any evident non-

compliance with rules of use, safety and protection.

INSTRUCTIONS FOR USE

Start-up

The heater is factory set for operation without room

thermostat.

If operation with room (remote) thermostat is desired, remove

the socket cover (Fig.1, No.1) and insert the thermostat plug into
the socket.

Fill the tank with proper fuel.

Connect the supply plug to a 110V ~ 60 Hz single phase earthed

socket. The green lamp indicates that the heater is powered.

WARNING: THE APPLIANCE MUST BE GROUNDED

1

2

3

4

Figure 1

Содержание HeatStar HS180ID

Страница 1: ...44135 216 881 5500 INDIRECT FIRED PORTABLE HEATER If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life WARN...

Страница 2: ...ERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER WARNING NOT FOR HO...

Страница 3: ...MODEL 180 300 Thermal power BTU hr 181 000 289 000 Air Flow Rating ft min 1475 2650 Oil Consumption gal hr 1 29 2 06 Fuel Nozzle 1 00 60 H 1 50 80 W Efficiency 87 1 88 5 Noise Level at 2m dB A 73 73...

Страница 4: ...contact with the combustion chamber that can be reached through the inspection cover To reset the thermostat unplug the heater open the inspection cover and push the reset button on the thermostat bo...

Страница 5: ...ce personnel Heater starts flame does Clogged nozzle Clean or replace not ignite and then heater Flame sensor receives an external Check for external lights sun lamps etc locks out light signal during...

Страница 6: ...eater Operating Instructions and Owner s Manual EV Fuel Solenoid Valve TR Ignition Transformer M Motor SL Warning Lamp TS Safety Thermostat FS Fuse FC Flame Sensor PL Reset Button IN Switch TH Room Th...

Страница 7: ...7 Operating Instructions and Owner s Manual ENERCO GROUP INC Indirect Fired Portable Heater THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 8: ...hip If a part is damaged or missing call our Technical Support Department at 800 251 0001 Address any Warranty Claims to the Service Department Enerco Group Inc 4560 W 160TH ST Cleveland Ohio 44135 In...

Отзывы: