background image

5

Operating Instructions and Owner’s Manual

Enerco | Catalytic Heater

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

GAS SUPPLY

• 

The LP-gas cylinder(s) used must 
be constructed and marked in 
accordance with the specifications 
for LP-gas cylinders of the U.S. 
Department of Transportation 
(DOT).

• 

Use only VAPOR WITHDRAWAL 
propane supply. If there is any 
question about vapor withdrawal, 
ask your propane dealer.

• 

The installation of the heater must 
conform to local codes or, in the 
absence of local codes, with the 
National Fuel Gas Code, ANSI 
Z223.1.

• 

This heater is designed to operate 
with an inlet pressure of 11 W.C. 
(.40 PSIG, 2.8 kPA). Do not install 
directly to a propane (LP) gas tank 
or cylinder.

• 

The supply line must be equipped 
at the cylinder with a listed 
low pressure propane (LP) gas 
regulator set to deliver the 
specified pressure. The high 
pressure propane (LP) gas line 
between the propane (LP) gas 
supply source and the regulator 
must be equipped with an excess 
flow valve to limit the escape of 
fuel in case of a break in the line.

Observe these operating 
precautions:

• 

Due to high temperatures, the 
heater should be located out of 
traffic and away from furniture and 
draperies.

• 

Children and adults should be 
alerted to the hazard of high 
surface temperature and should 
stay away to avoid burns or 
clothing ignition.

• 

Young children should be carefully 
supervised when they are in the 
same room with the heater.

• 

Do not place clothing or other 
flammable material on or near the 
heater.

• 

Installation and repair should be 
done by a qualified service person. 
The heater should be inspected 
before use and at least annually by 
a professional service person.

• 

WARNING: Any change to this 
heater or its controls or attempts 
to clean the catalytic pad can be 
dangerous.

• 

The safety grill, if removed for 
servicing, must be replaced prior 
to operating the heater. DO NOT 
OPERATE WITH DUST SHIELD 
COVER IN PLACE!

• 

IMPORTANT: The operation of 
the heater is such that, on initial 
lighting from cold start, a slight 
odor of gas may be noticed for 

a short period of time — this is 

normal. If odor persists, shut off 
heater and have it serviced.

• 

IMPORTANT: REMOVE DUST 
SHIELD BEFORE USE.

• 

Do not attempt to clean catalytic 
pad. Follow cleaning instructions 
accompanying heater.

Fuel

• 

This heater is designed for use with 
HD-5 propane (LP) gas only. Do not 
attempt to convert it to use with other 
gases or liquid fuels. Use of any gases 
other than HD-5 propane (LP) gas may 
cause damage to the catalytic heating 
element.

Locations

• 

Refer to Specifications table on page 3 for 
minimum clearances from combustibles.

IMPORTANT:

 When heater is installed 

using the feet directly on carpeting, tile, 
or other combustible material other 
than wood flooring, the heater must 
be installed on a metal or wood panel 
extending the full width and depth of 
the heater.

• 

This Heater may be used in a 
recreational enclosure or temporary 
construction work enclosure with a 
remote refillable propane (LP) gas 
cylinder ONLY when the cylinder is 
located outdoors and the heater is 

used with Enerco Hose No. F271161, 
F271161-60, and F271161-144. 

Figure 1

SAFETY INSTR

UCTIONS

Model

Tank 

Weight    

(lbs)

Setting

Heater 

Rate 

(BTU/HR)

Maximum Oper-

ating Time with 

Full Tank (hrs)

MHCAT3LP

20

HI

3000

143

MHCAT3LP

20

LO

 2700

159

MHCAT6LP

20

HI

6000

72

MHCAT6LP

20

LO

4000

107

MHCAT8LP

20

HI

8000

54

MHCAT8LP

20

LO

5000

86

Table 1

Содержание ECAT3LP

Страница 1: ...ately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department or a qualified service agency Installation an...

Страница 2: ...fuel supply 4 Leave the area immediately 5 Allow gas to dissipate 5 minutes before relighting the appliance Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this o...

Страница 3: ...le 4 x 2 opening 3 x 2 opening and 3 x 1 opening respectively at the ceiling and at floor level for adequate ventilation during operation Do not use other fuel burning appliances inside GAS PRESSURE A...

Страница 4: ...ane LP gas odor may differ in intensity at different levels Since propane LP gas is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas odor If you continu...

Страница 5: ...by a qualified service person The heater should be inspected before use and at least annually by a professional service person WARNING Any change to this heater or its controls or attempts to clean th...

Страница 6: ...thsoapywateratthethreaded connection on the side of the heater DO NOT USE ANY EXPOSED FLAME TO CHECK FOR LEAKS DO NOT OVERTIGHTEN Wall Installation Your heater may be installed in a variety of fixed l...

Страница 7: ...eterioration are all possible causes 2 The heater has been allowed time to cool down completely 3 It has been determined that there is no leaked or otherwise unburned propane LP gas present in the sur...

Страница 8: ...ouple The flame will surround the thermocouple just below the tip Figure 6 shows a correct pilot flame pattern and also shows an incorrect pilot flame pattern The incorrect pilot flame pattern is not...

Страница 9: ...or 14 mm wrench to remove the compression nut connecting the inlet gas tube to the enclosure See Figure 1 1 4 Lift up on the control bracket assembly to remove it from the heater See Figure 12 5 Compl...

Страница 10: ...Refer to Figure 4 in the Installation section on page 6 to replace the feet OFFSEASON If the heater is to left OFF for a considerable period of time the propane LP gas supply to the heater should be...

Страница 11: ...ve contamination 5 Replace control valve SYMPTOM Spark electrode produces spark but pilot does not light CAUSE REMEDY 1 No gas to heater 1 Connect hose to heater and turn on valve at remote cylinder 2...

Страница 12: ...acket 1b 36834 36834 36834 Handle grip 2 36832 36832 36832 Burner Access Panel 3 36818 36818 36818 Lower Access Panel 4 36817 36817 36817 Foot 5 78436 78436 78436 Foot Pad Rubber 6 32123 32123 32123 V...

Страница 13: ...ing Instructions and Owner s Manual Enerco Catalytic Heater NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NEVER LEAVE THE HEATER UNATTENDED WHILE BURN...

Страница 14: ...is product free of charge if it has been proven to be defective within the 1 year period and is returned at customer expense with proof of purchase to Enerco Group Inc within the warranty period DISCL...

Страница 15: ...iales lesiones o muertes No almacene ni utilice gasolina ni ning n otro vapor ni l quido inflamable cerca de este ni de ning n otro artefacto QU HACER SI DETECTA OLOR A GAS No intente encender el arte...

Страница 16: ...mediatamente el rea 5 Permita que el gas se disipe durante 5 minutos antes de volver a encender el artefacto No almacene ni utilice gasolina ni ning n otro vapor ni l quido inflamable cerca de este ni...

Страница 17: ...emplo una abertura de 4 x2 3 X2 y 3 x1 respectivamente en el techo y al nivel del piso para una ventilaci n adecuada durante su funcionamiento No use otros electrodom sticos que queman combustible en...

Страница 18: ...ibiendo el olor a gas no importa cu n poco sea proceda como si fuera una fuga seria Tome medidas inmediatamente como se explic anteriormente ATENCI N PUNTOS IMPORTANTES A RECORDAR El gas propano LP ti...

Страница 19: ...ejados para evitar quemaduras o quemaduras en la ropa Los ni os peque os deben estar vigilados cuidadosamente cuando est n en la habitaci n en donde se encuentre el calefactor No coloque ropa u otro m...

Страница 20: ...conecte el otro extremo de la manguera a la v lvula del cilindro de suministro de gas propano LP o al punto de conexi n Apriete todas las conexiones de la manguera NO use sellador de roscas en ninguna...

Страница 21: ...a del regulador falla mec nica del calefactor o deterioro de la almohadilla catal tica hayan sido todas las causas posibles 2 Se haya permitido que el calefactor se enfr e por completo 3 Se haya deter...

Страница 22: ...correcto y tambi n muestra un patr n de llama piloto incorrecto El patr n de llama piloto incorrecto no est tocando la termocupla Esto har que se enfr e la termocupla Cuando la termocupla se enfr e el...

Страница 23: ...ipal del calefactor Consulte la Figura 10 2 Remueva la perilla de la v lvula separ ndola del calefactor 3 Use una llave de 9 16 o de 14 mm para remover la tuerca de compresi n que conecta el tubo de g...

Страница 24: ...a almohadilla Siga los pasos para reemplazar el quemador cuando tenga que reemplazar la almohadilla catal tica Reemplazo de las patas Consulte la Figura 4 en la secci n Instalaci n de la p gina 6 para...

Страница 25: ...a de control S NTOMA El electrodo de encendido produce chispa pero el piloto no se enciende CAUSA SOLUCI N 1 No llega gas al calefactor 1 Conecte la manguera al calefactor y abra la v lvula en el cili...

Страница 26: ...6834 36834 36834 Manija mango 2 36832 36832 36832 Panel de acceso al quemador 3 36818 36818 36818 Panel de acceso inferior 4 36817 36817 36817 Pata 5 78436 78436 78436 Almohadilla para pata goma 6 321...

Страница 27: ...13 S Instrucciones de uso y manual del usuario Enerco Calefactor catal tico NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING NUNCA DEJE EL CALEFACTOR DESATENDIDO MIENTRAS EST ENCENDIDO NOTAS...

Страница 28: ...r a o tras realizada la compra siempre y cuando el cliente costee la devoluci n y presente el comprobante de compra a Enerco Group Inc dentro del per odo de garant a DESCARGO DE RESPONSABILIDAD Esta g...

Отзывы: