background image

Appareil de chauffage au prop

ane à air pulsé pour chantier de construction - Modèle nº 55FA

V

9

Guide d'utilisation et instructions de fonctionnement

Enerco Group, Inc. | App

areil de chauffage à air pulsé au gaz prop

ane pour

chantier de construction

F. N

º

N° ART.

DESCRIPTION

QT

É

55FAV

85FAV

125FAV

1

21654

21671

21671

Grille du moteur

1

2

21652

21551

21551

Moteur

1

3

26086

26086

27898

Ventilateur

1

4

21729

21670

21998

Coque extérieure

1

21730

21672

21999

Coque extérieure – Modèle TS1

5

27095

27095

27095

Poignée

1

6

27094

27094

27094

Fixation de poignée à clip

2

7

26121

27433

27433

Raccord, coude mâle

1

8

21082

21083

21083

Bougie d’allumage

1

9

21751

21751

22003

Limiteur supérieur

1

10

23036

23036

Support thermocouple

1

11

23787

23787

Entretoise thermocouple

1

12

21930

21673

22002

Orifice, LP

1

13

21651

21674

22001

Cylindre médian

1

14

23037

23037

23037

Écrou de bougie (2-55FAV)

3

15

21931

21750

22004

Ve

ill

eu

se

1

16

23038

23038

23038

Fixation, écrou d’orifice

1

17

21935

21668

21668

Tube de carburant

1

18

26654

26654

26654

Thermocouple 13" Lg avec JB1

19

23044

23044

Support allumage / relais

1

20

26641

26641

26641

Plaque de bornes

1

21

26065

26065

26065

Entretoise, acier

1

22

21811

21811

21811

Relais

1

23

23275

23275

23275

Allumeur, transistorisé

1

24

26079

26079

26079

Entretoise PC

3

25

26265

26265

26265

Raccord, coude de rue

2

26

27431

27404

27897

Vanne, débit variable

1

27

23141

27405

27405

Raccord, connecteur femelle1

28

26225

26227

Douille pression

1

RÉF. Nº

N° 

ART.

DESCRIPTION

QT

É

55FAV

85FAV

125FAV

29

26224

27158

Douille pression, 1/2

1

30

26133

26133

26133

raccord, accouplement

1

31

26127

26127

26127

Raccord, connecteur mâle

1

32

27285

27285

27285

Vanne thermoélectrique

1

33

26223

26223

26223

Douille anti-tension

1

34

21036

21036

21036

Cordon d’alimentation

1

35

26433

26433

26433

POL débit excessif 1/4 MPT

1

36

26257

26257

26257

Régulateur 28" C.E.

1

37

26152

26152

26152

Tuyau, LP

1

38

24017

24019

24019

Panneau, partie inférieure

1

40

24020

24022

24022

Boîte de commande

1

*

24023

24025

24025

Plaque de soulèvement

1

*

25026

25026

25026

Bouton de soulèvement

1

*

26189

Borne “Y”

2

*

23676

Support, montage du moteur

1

*

26226

Douille universelle

1

*

21667

21667

21667

Assemblage tuyau/régulateur

1

*

70056

70056

70056

Manuel d’utilisation

1

*

28733

28507

28510

Étiquette, modèle

1

*

27783

28784

28784

Étiquette, instr. d’utilisation

1

*

26374

26374

26374

Étiquette, mise à la terre

1

*

27709

27709

27709

Étiquette, carburant

1

*

27503

27503

27503

Étiquette, sch. câblage

1

*

26373

26373

26373

Étiquette, rotation ventilateur

1

*

28203

28203

28203

Étiquette suspendue, LP

1

*

27704

27704

27704

Étiquette, avertissement

1

*

26375

26375

26375

Étiquette, réglage de hauteur1

*

26376

26376

26376

Étiquette, réglage Btu/h

1

*

Composant non illustré sur la vue éclatée.

Содержание BUDDY-PRO TS125FAV

Страница 1: ...able heater It uses air oxygen from the area in which it is used Adequate combustion and ventilation air must be provided Refer to page 3 READINSTRUCTIONSCAREFULLY Readand follow all instructions Plac...

Страница 2: ...MMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE ORAIRBORNE COMBUSTIBLES OR PRODUCTS SUCHAS GASOLINE SOLVENTS PAINT THINNER DUST PARTICLES OR UNKNOWN CHEMICA...

Страница 3: ...tion efficiency it still produces small amounts of carbon monoxide Carbon monoxide called CO is toxic We can tolerate small amounts but not a lot CO can build up in a heated space and failure to provi...

Страница 4: ...odor is detected IMMEDIATELY DISCONTINUE operation until the source of gas has been located and corrected Read enclosed Odor fade and Propane Sheet for additional information about detecting propane...

Страница 5: ...andareabeforeyoureturn Properlytrained servicepeoplemustrepairanyleaks checkforfurther leakages andthenrelighttheapplianceforyou ODOR FADING NO ODOR DETECTED Some people cannot smell well Some people...

Страница 6: ...d from the heater and stored out of doors and in accordance with Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum GasesANSI NFPA58andCSAB149 1 NaturalGasand Propane Installati...

Страница 7: ...chart 3 Readthecylindersizerequired Allheatersshouldhave fullcylinders goodaircirculation nofrostoncylinders MAXIMUM OPERATING TIME HOURS MAXIMUM OPERATING TIME HOURS MAXIMUM OPERATING TIME HOURS 55...

Страница 8: ...IRINGDIAGRAMS 8 Operating Instructions and Owner s Manual Enerco Group Inc ForcedAir Propane Construction Heater CONNECTION DIAGRAM MOTOR IGNITOR B SCHEMATIC DIAGRAM HIGH LIMIT SWITCH THERMOCOUPLE SPA...

Страница 9: ...24 26079 26079 26079 Spacer PC Standoff 3 25 26265 26265 26265 Ftg Elbow Street 2 26 27431 27404 27897 Variable Rate Valve 1 27 23141 27405 27405 Ftg Female Connector 1 28 26225 26227 Snap Bushing 1...

Страница 10: ...of the Company There are no other warranties express or implied Specifically there is no warranty of fitness for a particular purpose and there is no warranty of merchantability In no event shall the...

Страница 11: ...L entreprise r parera ou remplacera sa discr tion les produits retourn s port pay par l acheteur au fabricant dans la p riode de un an et jug s par l entreprise comme pr sentant des d fauts de mat ri...

Страница 12: ...079 26079 Entretoise PC 3 25 26265 26265 26265 Raccord coude de rue 2 26 27431 27404 27897 Vanne d bit variable 1 27 23141 27405 27405 Raccord connecteur femelle 1 28 26225 26227 Douille pression 1 R...

Страница 13: ...mande Conduite T B maximum 1441 Noir 127 mm 5 po Relais Central T B 1442 Blanc 127 mm 5 po Relais Retour T B 1806 Orange 152 mm 6 po Relais Bo te de jonction du thermocouple 1806 Orange 152 mm 6 po Re...

Страница 14: ...r senter aucun signe de givre DUR E DE FONCTIONNEMENT MAX HEURES DUR E DE FONCTIONNEMENT MAX HEURES DUR E DE FONCTIONNEMENT MAX HEURES 55 000 BTU H 16 1 kW 85 000 BTU H 33 4 kW 125 000 BTU H 49 1 kW T...

Страница 15: ...ou endommag de quelque fa on remplacez le par la pi ce n 73786 3 Coupez l alimentation en gaz propane liqu fi quand l appareil n est pas utilis 4 Quand l appareil de chauffage est rang l int rieur la...

Страница 16: ...du gaz s chappe Assurez vous qu ils aient a r l immeuble avant d y retourner Le personnel d entretien exp riment doit colmater toute fuite v rifier la pr sence d autres fuites puis se charger d allum...

Страница 17: ...age jusqu ce que la source d mission du gaz ait t localis e et colmat e Veuillez lire le feuillet Substance odorante et gaz propane ci joint pour obtenir plus de pr cisions relatives la d tection des...

Страница 18: ...ffage est presque compl te il produit quand m me de petites quantit s de monoxyde de carbone Le monoxyde de carbone appel CO est toxique Notre organisme ne peut en supporter que de faibles quantit s I...

Страница 19: ...JAMAIS L APPAREIL DE CHAUFFAGE DANS UN LOCAL QUI CONTIENT OU RISQUE DE CONTENIR DES PARTICULES COMBUSTIBLES EN SUSPENSION DANS L AIR OU DES PRODUITS TELS QUE DE L ESSENCE DES SOLVANTS DU DILUANT PEINT...

Страница 20: ...e l oxyg ne de l air ambiant Une circulation d air ad quate doit tre assur e pour la combustion et la ventilation Voir page 3 LISEZ SOIGNEUSEMENT LES INSTRUCTIONS Conservez les instructions en s curit...

Отзывы: