WARNING:

USE ONLY MANUFACTURER’S REPLACEMENT PARTS.

USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.
REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE
FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE
AGENCY. MR. HEATER HOSES F273701 AND F273702 ARE
SPECIFICALLY DESIGNED FOR USE WITH THIS HEATER. USE OF OTHER
HOSES MAY CAUSE THE HEATER TO BECOME INOPERABLE.

PARTS ORDERING INFORMATION:

PURCHASING: Accessories may be purchased at any Mr. Heater local dealer or direct
from the factory
FOR INFORMATION REGARDING SERVICE
Please call Toll-Free 800-251-0001 • www.mrheater.com
Our office hours are 8:30 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of problem in all
communication.

LIMITED WARRANTY
The company warrants this product to be free from imperfections in material or workmanship,
under normal and proper use in accordance with instructions of The Company, for a period of
one year from the date of delivery to the buyer. The Company, at its option, will repair or
replace products returned by the buyer to the factory, transportation prepaid within said one
year period and found by the Company to have imperfections in material or workmanship.

If a part is damaged or missing, call our Technical Support Department at 800-251-0001.

Address any Warranty Claims to the Service Department, Enerco Group, Inc., 4560 W. 160TH
ST., CLEVELAND, OHIO 44135. Include your name, address and telephone number and include
details concerning the claim. Also, supply us with the purchase date and the name and
address of the dealer from whom you purchased our product.

The foregoing is the full extent of the responsibility of the Company. There are no other
warranties, express or implied. Specifically there is no warranty of fitness for a particular
purpose and there is no warranty of merchantability. In no event shall the Company be liable
for delay caused by imperfections, for consequential damages, or for any charges of the
expense of any nature incurred without its written consent. The cost of repair or replacement
shall be the exclusive remedy for any breach of warranty. There is no warranty against
infringement of the like and no implied warranty arising from course of dealing or usage of
trade. This warranty will not apply to any product which has been repaired or altered outside
of the factory in any respect which in our judgment affects its condition or operation.

Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you. This Warranty
gives you specific legal rights, and you may have other rights which vary from state to
state.

ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 216-916-3000
Mr. Heater is a registered trademarks of Enerco Group, Inc.
© 2003, Enerco/Mr. Heater. All rights reserved

ANSI Z83.7/CGA 2.14-2000

Enerco Group, Inc. reserves the right to make changes at any time, without notice or
obligation, in colors, specifications, accessories, materials and models.

®

®

READ INSTRUCTIONS CAREFULLY: Read and
follow all instructions. Place instructions in a
safe place for future reference. Do not allow
anyone who has not read these instructions to
assemble, light, adjust or operate the heater.

MH55FAV, MH85FAV
MH125FAV

MODEL

MODEL

OPERATING INSTRUCTIONS AND OWNER’S MANUAL

MR. HEATER

HEATSTAR

HS55FAV, HS85FAV
HS125FAV

10

Operating Instructions and Owner’s Manual

Enerco Group, Inc.| Forced Air Propane Construction Heater

TS55FAV,
TS125FAV

BUDDY-PRO

MODEL

70056   Rev. A   5/05

Содержание BUDDY-PRO TS125FAV

Страница 1: ...able heater It uses air oxygen from the area in which it is used Adequate combustion and ventilation air must be provided Refer to page 3 READINSTRUCTIONSCAREFULLY Readand follow all instructions Plac...

Страница 2: ...MMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE ORAIRBORNE COMBUSTIBLES OR PRODUCTS SUCHAS GASOLINE SOLVENTS PAINT THINNER DUST PARTICLES OR UNKNOWN CHEMICA...

Страница 3: ...tion efficiency it still produces small amounts of carbon monoxide Carbon monoxide called CO is toxic We can tolerate small amounts but not a lot CO can build up in a heated space and failure to provi...

Страница 4: ...odor is detected IMMEDIATELY DISCONTINUE operation until the source of gas has been located and corrected Read enclosed Odor fade and Propane Sheet for additional information about detecting propane...

Страница 5: ...andareabeforeyoureturn Properlytrained servicepeoplemustrepairanyleaks checkforfurther leakages andthenrelighttheapplianceforyou ODOR FADING NO ODOR DETECTED Some people cannot smell well Some people...

Страница 6: ...d from the heater and stored out of doors and in accordance with Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum GasesANSI NFPA58andCSAB149 1 NaturalGasand Propane Installati...

Страница 7: ...chart 3 Readthecylindersizerequired Allheatersshouldhave fullcylinders goodaircirculation nofrostoncylinders MAXIMUM OPERATING TIME HOURS MAXIMUM OPERATING TIME HOURS MAXIMUM OPERATING TIME HOURS 55...

Страница 8: ...IRINGDIAGRAMS 8 Operating Instructions and Owner s Manual Enerco Group Inc ForcedAir Propane Construction Heater CONNECTION DIAGRAM MOTOR IGNITOR B SCHEMATIC DIAGRAM HIGH LIMIT SWITCH THERMOCOUPLE SPA...

Страница 9: ...24 26079 26079 26079 Spacer PC Standoff 3 25 26265 26265 26265 Ftg Elbow Street 2 26 27431 27404 27897 Variable Rate Valve 1 27 23141 27405 27405 Ftg Female Connector 1 28 26225 26227 Snap Bushing 1...

Страница 10: ...of the Company There are no other warranties express or implied Specifically there is no warranty of fitness for a particular purpose and there is no warranty of merchantability In no event shall the...

Страница 11: ...L entreprise r parera ou remplacera sa discr tion les produits retourn s port pay par l acheteur au fabricant dans la p riode de un an et jug s par l entreprise comme pr sentant des d fauts de mat ri...

Страница 12: ...079 26079 Entretoise PC 3 25 26265 26265 26265 Raccord coude de rue 2 26 27431 27404 27897 Vanne d bit variable 1 27 23141 27405 27405 Raccord connecteur femelle 1 28 26225 26227 Douille pression 1 R...

Страница 13: ...mande Conduite T B maximum 1441 Noir 127 mm 5 po Relais Central T B 1442 Blanc 127 mm 5 po Relais Retour T B 1806 Orange 152 mm 6 po Relais Bo te de jonction du thermocouple 1806 Orange 152 mm 6 po Re...

Страница 14: ...r senter aucun signe de givre DUR E DE FONCTIONNEMENT MAX HEURES DUR E DE FONCTIONNEMENT MAX HEURES DUR E DE FONCTIONNEMENT MAX HEURES 55 000 BTU H 16 1 kW 85 000 BTU H 33 4 kW 125 000 BTU H 49 1 kW T...

Страница 15: ...ou endommag de quelque fa on remplacez le par la pi ce n 73786 3 Coupez l alimentation en gaz propane liqu fi quand l appareil n est pas utilis 4 Quand l appareil de chauffage est rang l int rieur la...

Страница 16: ...du gaz s chappe Assurez vous qu ils aient a r l immeuble avant d y retourner Le personnel d entretien exp riment doit colmater toute fuite v rifier la pr sence d autres fuites puis se charger d allum...

Страница 17: ...age jusqu ce que la source d mission du gaz ait t localis e et colmat e Veuillez lire le feuillet Substance odorante et gaz propane ci joint pour obtenir plus de pr cisions relatives la d tection des...

Страница 18: ...ffage est presque compl te il produit quand m me de petites quantit s de monoxyde de carbone Le monoxyde de carbone appel CO est toxique Notre organisme ne peut en supporter que de faibles quantit s I...

Страница 19: ...JAMAIS L APPAREIL DE CHAUFFAGE DANS UN LOCAL QUI CONTIENT OU RISQUE DE CONTENIR DES PARTICULES COMBUSTIBLES EN SUSPENSION DANS L AIR OU DES PRODUITS TELS QUE DE L ESSENCE DES SOLVANTS DU DILUANT PEINT...

Страница 20: ...e l oxyg ne de l air ambiant Une circulation d air ad quate doit tre assur e pour la combustion et la ventilation Voir page 3 LISEZ SOIGNEUSEMENT LES INSTRUCTIONS Conservez les instructions en s curit...

Отзывы: