18
19
Storage screen
Highlight the
Alarm Out / Notify
tab and the
System Check - Alarm Out / Notify
screen displays.
System Check (Alarm Out / Notify) screen
Highlight the box under the
Alarm Out
heading and press the
button. A drop menu displays available alarm outputs for the recording problem.
Highlight the desired alarm output from the external alarm out terminal or internal buzzer, and press the
button.
NOTE: Alarm Out cannot be set to Check Point - System.
Highlight the box under
Notify
and press the
button. This toggles between
On
and
Off
. When it is
On
, the DVR notifies the remote site of its
System (Good)
and
Record (Bad)
.
Storage Screen
Highlight
Storage
in the Main menu and press the
button. The
Storage
setup screen appears.
The
Type
field displays the type and capacity of storage devices.
The
Status
field displays the device status or fault conditions. (Good, Disk Bad, S.M.A.R.T. Alert, High Temperature, or Not installed)
NOTE: If the DVR senses
S.M.A.R.T. Alert
or
High Temperature
, the S.M.A.R.T. Monitoring Information screen will appear.
Once the S.M.A.R.T. Monitoring Information screen displays, replacing the hard disk drive is recommended, usually within 24 hours.
NOTE: The S.M.A.R.T. Monitoring Information screen appears only in the monitoring mode.
The
°C
field displays the temperature of the storage device.
The
Usage
field displays the device usage.
The DVR can be set to react to storage problems by activating an internal buzzer or external alarms, display the warning message and/or notifying a PC
running RAS (Remote Administration System). Highlight the box beside
Storage Problem Action: Alarm Out / Notify
and press the
button to select from
Beep, the alarm output terminal that you want to associate with the storage problem event, and/or Notify.