background image

Wallbox

Adspace

Assembly manual

Enelion Sp. z o.o.

[email protected]

Содержание Wallbox Adspace

Страница 1: ...Wallbox Adspace Assembly manual Enelion Sp z o o info enelion com ...

Страница 2: ...Copyright Enelion Sp z o o The manual may change as the product develops The information provided may not be correct All rights reserved Revision V 3 4 Number of pages 21 Released August 3 2021 ...

Страница 3: ...iteria 8 4 Assembly 9 4 1 Preparing the installation 9 4 2 Selection of bolts and anchors 9 4 3 Cable routes 9 4 4 Mounting the device 10 5 Connection 11 5 1 Power connection 11 5 1 1 Standard power connection 12 5 1 2 Power connection in version with MID meter 13 5 1 3 RCM B Connection 13 5 2 Connection of communication wires 14 5 3 Enelion Chain 14 5 4 Internet connections via Ethernet interface...

Страница 4: ...re that the module packages contain all the elements Current version of the operation manual can be accessed at http enelion com en help See the contents of the manual before initiating any activities related to the installation or the activation of the charger 3 Contents ...

Страница 5: ...andards The device does not have a built in switch The de vice activates when the supply voltage is applied The power supply cut off function must be provided by the appropriate electrical installation devices described in the assembly manual Except in emergencies the de vice must not be turned off during the charging process It is forbidden to supply the power to the device when the device casing...

Страница 6: ...i vated providing dynamic load balancing thus reducing the number of devices that require an Internet connec tion and optimizing the use of power in charging vehi cles All Enelion devices can be fitted with Enelion Bridge an add on to be purchased separately It equips the devices with Smart functions and facilitates their con nection to a remote management system OCPP 1 6 compliant via the Interne...

Страница 7: ...el until it is released from the housing and tilted slightly Fig 6 Front panel slightly tilted 6 Holding the front panel in the same plane slide it downwards from the top groove of the device Fig 7 Removing the front panel from the device housing 7 Slowly continue to pull out the front panel aware of the socket lock that could hook onto the hous ing Fig 8 Pulling out the front panel 8 The front pa...

Страница 8: ...ur wire cable The cross section of the power supply cables must be selected by an authorized electrician depending on the distance from the switchboard and other conditions per tinent to the location To obtain the maximum charging power in wall mounted devices the use of cables with a conductor cross section not greater than 6 mm2 is rec ommended The maximum cross section of the power supply cable...

Страница 9: ...high exposure to sunlight which could cause overheating Do not install the device near heat sources or in small closed spaces e g in a box It is forbidden to install a power cord that does not com ply with the guidelines in section 3 1 Recommended power connection It is forbidden to install the device in potentially explosive environment Local regulations for electrical installations fire preven t...

Страница 10: ... method of assembly depending on the mounting surface 1 four mounting holes are positioned on the plan of a rectangle with dimensions of 960 mm x 96 mm width x height 2 mounting holes have a diameter of 5 5 mm 3 the device weighs between 2 8 kg 3 kg 4 mounting must provide stability for the device to withstand significant forces affecting it when plug ging and unplugging the charging cable in the ...

Страница 11: ...e facilitating the installation 1 Determine the final location of the device using the attached template and the level and mark the mounting holes The template marks the mount ing holes the outline of the rear wall of the device the axes of the glands both in the version with a gland in the upper and lower part of the device and the optimal cable lengths Mounting holes should be at least 5 cm from...

Страница 12: ...ectly to the approved integrated MID meter Charging module Type 2 socket with RCMB 6mA DC Type 2 socket Type 2 socket Charging module Type 2 socket with RCMB 6mA DC Terminal block Terminal block Terminal block Terminal block Housing Charging module Type 2 socket with RCMB 6mA DC Charging module Type 2 socket with RCMB 6mA DC Variant 1 Variant 2 Housing meter meter fuse fuse Fig 13 Diagrams of conn...

Страница 13: ...nnection INFO For both charging sockets to function in Ene lion Wallbox Adspace the voltage must be sup plied to the electrical connection clamps of both charge controllers The steps described below should be applied to the terminals of both charg ing sockets 1 Run the left socket power supply cable along the bottom part of the device below the backlight shield 2 Prepare the power supply cable Rem...

Страница 14: ...nsert the power cables into the terminals of the MID meter and tighten them Unless otherwise marked on the label of the de vice make a standard connection in accordance with the markings on the meter The PE protec tive conductor should be connected to the pre pared coupling Fig 18 Recommended connection when apply ing a MID meter MID meter communication connection should be done according to the d...

Страница 15: ...e treated as a section between devices and all the guidelines described below should be applied 5 3 Enelion Chain If the communication between the devices is expected to be via Enelion Chain network the cables should be connected to the charge controller Two cores of the communication cable and the screen grounding are used for communication To connect correctly 1 Prepare communication cables 2 a ...

Страница 16: ...n variant A Fig 25 Diagram of Enelion Chain communica tion cables connection variant B 4 Use termination for devices at the beginning and end of the network In case of variant A place terminating jumper on the marked headers Fig 28 In case of variant B termination is done by slide the switch down to show white square In alternate version if there is no switch place a jumper on two pins in the head...

Страница 17: ... for communication cables 2 Terminate the cable with the RJ45 connector ac cording to TIA 568A B to 100BaseT Fig 30 Termination of the Ethernet cable accord ing to TIA 568A B to 100BaseT 3 Connect the Ethernet cable to the WAN INTERNET socket of Enelion Bridge mod ule marked with number 2 Fig 31 Enelion Bridge module diagram 5 5 Backlight power supply The backlight module is powered from the termi...

Страница 18: ...wind o WARNING The device may only be opened by a qualified and authorized person 6 1 Cleaning The correct way to clean the charger is to wipe the housing with a microfiber cloth using a cleaning agent dedicated to anodized aluminum Plexiglas elements front panel and plastic elements socket should be cleaned with a microfiber cloth using a cleaning agent dedicated to cleaning windowpanes Other cle...

Страница 19: ...cuit current Effective value 6 kA according to EN 61439 1 Overcurrent protection Not included Protection to be made in accordance with the locally valid regulations and according to the type of the device Protection Class Class I Socket type 2x Type 2 standard socket 32 A 400 VAC in accordance with EN 62196 1 Mechanical data Dimensions width x height x depth 1000 mm x 249 mm x 156 mm Weight 7 kg 5...

Страница 20: ...rature range from 40 C do 80 C Permitted relative air humidity from 5 do 95 Elevation above the sea level maximum 2000 m Signs of installation faults Damaged varistors on PilotBox It means faulty connection powering cords o WARNING Above information may be the basis for exclu sion of warranty 19 Technical data ...

Страница 21: ......

Страница 22: ... 2021 ENELION Pana Tadeusza 50 80 123 Gdan sk Polska ...

Отзывы: