6.
Technical data
6.1.
Enelion Energy Guard
Electrical data
Nominal supply voltage
1x 230V AC / 3x 230V AC ( +-10%)
Network type
TN-C; TN-S; TN-C-S; TT
Voltage frequency
50 Hz/60 Hz
Overvoltage category
III according to EN 60664–1
Maximum value of measuring current
Depends on the current transformers (Home: 40 A, Busi-
ness:
100 A, 300 A, 500 A); possibility to individual
choose for higher value of current
Accuracy
Accuracy class 0,5
Maximum temporary overload*
100%
Bidirectional current measurement
Yes
Measurement point parameters
Three or one phase system (included correct amount of
measuring coils.)
Typical reaction time from switch on to
change the charging power
< 1,5 s
Maximum charging hold time
3 s, according with IEC 61296
Maximum charging station reaction time on
change of available power
5 s, (according with IEC 61296)
Maximum EnergyGuard reaction time on
higher current consumption detection
1 s
Maximum connection overload time**
9 s
Maximum connection current limitation
3 kA
*must be executed following conditions:
1. Connection was in 100% used by cars
2. At the same moment the external load has been
launched using 100% of the main connection
13