Operating
the generator
Stop
the device
Status at: April 2016
31
Turn the START-
STOP switch into the "OPERATION“
1.
setting until the battery and oil warning light is active.
Pull out the START- STOP switch
(see Figure 3-3-(8))
and
2.
turn this all the way to the right until the engine starts.
Only activate the starter briefly (max. 5-10 seconds). Never
start or run the engine with the battery disconnected.
The generator has started.
4.4
Stop the device
Turn the START-STOP switch
(seeFigure 3-3 -(8))
all the
1.
way to the left until the engine stops.
The generator is off.
4.5
Connecting up to consumers
Proceed as follows to connect appliances to the generator.
These requirements must be met:
generator started
device switched off
WARNING!
Electric shocks cause injury or death.
Do not earth the generator.
Do not connect protective conductor to an existing po-
tential equalisation line.
Do not connect the generator to an existing electrical
grid.
You can connect devices using Schuko or CEE sockets.
Note
Requirements
Connecting up to
consumers