Prosonic S FDU90/91/91F/92/93/95/96
28
Hauser
Product structure FDU95
010
Approval
C
IEC Ex ta/tb IIIC Da/Db
D
IEC Ex ma IIC T6 Gb, IEC Ex ta/tb IIIC Da/Db
E
ATEX II 1/2 D Ex ta/tb IIIC
H
ATEX II 3D
J
ATEX II 1/2 D Ex ta/tb IIIC, ATEX II 2G Ex ma IIC T6
P
FM Cl.II Div.1 Gr.E-G, zone 2,21,22
R
Non-hazardous area
T
CSA Cl.II Div.1 Gr.E-G, zone 2
U
CSA General Purpose
W
TIIS dust-Ex DP12 (in preparation)
1
NEPSI DIP A20/21 IP65
2
NEPSI Ex ma II T6, DIP A20/21 IP65
015
Temperature; blocking distance; material
1
-40 ... +80°C/176°F; 70 cm/2.3ft; membrane: 316L; PEcoated
2
-40 ... 150°C/302°F; 90 cm/2,9ft; membrane: 316L
020
Process connection (threaded boss)
G
Thread ISO228 G1, UP
N
Thread ANSI NPT1, UP
030
Cable length
1
5 m/16 ft
2
10 m/32 ft
3
15 m/49 ft
4
20 m/65 ft
5
25 m/82 ft
6
30 m/98 ft
8
... m (variable length, up to 300 m)
A
... ft (variable length, up to 985 ft)
040
Additional option
A
Basic version
L
5-point linearity protocol
(only to order with FMU9x trans 5-point linearity protocol)
995
Marking
1
Tagging (TAG)
FDU95 -
product designation