Heating jacket for Promass A, E, H, I, M, S, P
Technical data
Hauser
11
Flow rate
Heat transfer coefficient
DN
Flow rate* in heating jacket in [kg/h]
A
H, S, P
E
I
M
1
400
–
–
–
–
2
450
–
–
–
–
4
500
–
–
–
–
8
–
1600
400
700
350
15
–
1560
440
700
350
25
–
1520
500
650
350
40
–
1410
610
560
670
50
–
1200
850
450
1000
80
–
–
–
–
1500
* differencial pressure= 1bar
DN
Heat transfer coefficient*
α
in °C/h
A
H, S, P
E
I
M
1
150
–
–
–
–
2
120
–
–
–
–
4
80
–
–
–
–
8
–
210
250
65
220
15
–
205
235
65
220
25
–
200
220
60
200
40
–
180
180
50
165
50
–
160
100
40
110
80
–
–
–
–
25
* uninsulated