Technical data
Proline t-mass 65 PROFIBUS DP/PA
116
Hauser
11.7
Installation
Installation section
11.8
Environment
Ambient temperature
range
Standard: –20 to +60 °C (–4 to +140 °F)
Optional: –40 to +60 °C (–40 to +140 °F)
!
Note!
• Install the device in a shady location. Avoid direct sunlight, particularly in warm climatic
regions. (A protective sun cover is available on request)
• At ambient temperatures below –20 °C (–4 °F) the readability of the display may be
impaired.
Storage temperature
–40 to +80 °C (–40 to +176 °F), recom20 °C (+68 °F)
Degree of protection
Standard: IP 67 (NEMA 4X) for transmitter and sensor
Shock resistance
According to IEC 60068-2-31
Vibration resistance
Acceleration up to 1 g, 10 to 150 Hz, following IEC 60068-2-6
Electromagnetic
compatibility (EMC)
To IEC/EN 61326 and NAMUR recommendation NE 21
11.9
Process
Medium temperature
range
Sensor
t-mass F:
–40 to +100 °C (–40 to +212 °F)
t-mass I:
–40 to +130 °C (–40 to +266 °F)
Seals t-mass F
O-rings:
Viton FKM –20 to +100 °C (–4 to +212 °F)
Kalrez –20 to +100 °C (–4 to +212 °F)
EPDM –40 to +100 °C (–40 to +212 °F)
Bushing:
PEEK –40 to +100 °C (–40 to +212 °F)
Seals t-mass I
Bonded seals:
Kalrez –20 to +130 °C (–4 to +266 °F)
EPDM –40 to +130 °C (–40 to +266 °F)
Nitrile –35 to +130 °C (–31 to +266 °F)
Ferrule:
PEEK, PVDF –40 to +130 °C (–40 to +266 °F)
Note
We recommend special materials (Alloy and PVDF) for aggressive media (e.g. chlorine or
ozone). Please contact your Hauser sales center for clarification.