Commissioning Instructions for PTB gas approval Proline Promass 84
Table of contents
Hauser
3
Table of contents
General information . . . . . . . . . . . . . . . 4
How to use this document . . . . . . . . . . . . . . . . . . . . 4
Components of the measuring system . . . . . . . . . . . 4
Identification . . . . . . . . . . . . . . . . . . . . 5
Device designation and versions . . . . . . . . . . . . . . 6
Nameplates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Wiring . . . . . . . . . . . . . . . . . . . . . . . . 12
Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . 12
Electrical connection of measuring unit . . . . . . . . . 13
Electrical connection of remote version . . . . . . . . . 14
Operation and commissioning . . . . . . 15
Operating options . . . . . . . . . . . . . . . . . . . . . . . . . 15
Hardware configurations . . . . . . . . . . . . . . . . . . . . 15
Quick setups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Operation subject to legal metrological
control ("Custody transfer"). . . . . . . . 16
Placing on market of measuring devices subject to legal
metrological control, inspection
of operational devices . . . . . . . . . . . . . . . . . . . . . . 16
Requirements for commissioning at point
of installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Requirements for usage . . . . . . . . . . . . . . . . . . . . . 17
Security measures . . . . . . . . . . . . . . . . . . . . . . . . . 17
Zero point adjustment . . . . . . . . . . . . . . . . . . . . . . 18
Configuring the measuring device for operation
subject to legal metrological control . . . . . . . . . . . 19
Sealing of the measuring device . . . . . . . . . . . . . . . 20
Unlocking the measuring device . . . . . . . . . . . . . . 21
Technical data . . . . . . . . . . . . . . . . . . 22
Overview of technical data relevant to
custody transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Custody transfer . . . . . . . . . . . . . . . . . . . . . . . . . . 28
System units
Configuration . 28
System units
Add. configuration . . . . . . . . . . . . . . . . . . . . . . 29
Special units
Arbitrary unit . . 29
Quick setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Control
Basic config. . . . . . . . . . . . . 30
Control
Unlocking/locking . . . . . . . 30
Main line
Configuration . . . . . 30
Main line
Multiplex . . . . . . . . 30
Additional line
Configuration . 30
Additional line
Multiplex . . . . 31
Information line
Configuration 31
Information line
Multiplex . . . 31
Totalizer 1 to 3
Configuration . . . . 31
Handling totalizer . . . . . . . . . . . . . . . . 32
Current output
Configuration . . . . . 32
Current output
Operation . . . . . . . . 32
Pulse/freq. output
Configuration . . . 33
Pulse/freq. output
Operation . . . . . . 35
Relay output
Configuration . . . . . . . 36
Relay output
Operation . . . . . . . . . . 36
Status input
Configuration . . . . . . . . . 36
Status input
Operation . . . . . . . . . . . . 36
Process parameter
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Process para.
EPD parameter . 37
Process para.
Ref. parameter . . 37
Process parameter
Adjustment 38
Process para.
Pressure correct. 38
System parameter
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Sensor data
Configuration . . . 38
Sensor data
Flow coeff. . . . . . 39
Sensor data
Density coeff. . . . 39
System
Configuration . . . . . . . . . 39
System
Operation . . . . . . . . . . . 40
Version-info
Device . . . . . . . . . . 40
Version-info
Sensor . . . . . . . . . . 40
Version-info
Amplifier . . . . . . . . 40
Version-info
I/O module . . . . . . 41
Application
Test points . . . 41
Application
Monitoring . . 41
Application
Gas measurement . . . . . . . . . . . . . . . . . . . . . . . 42