Nominal diameter
ASME
[mm]
[in]
Pressure rating
[lbs]
65
2 ½
Class 150
–
80
3
Class 150
27.6
100
4
Class 150
32.0
125
5
Class 150
–
150
6
Class 150
52.9
200
8
Class 150
95.9
Measuring tube specification
Nominal
diameter
Pressure rating
Process connection internal diameter
EN
(DIN)
ASME
AS 2129 AS 4087
JIS
PFA
PTFE
[mm]
[in]
[bar]
[psi]
[bar]
[bar]
[bar]
[mm]
[in]
[mm]
[in]
15
½
PN 40
Class 150
–
–
20K
–
–
15
0.59
25
1
PN 40
Class 150
Table E
–
20K
23
0.91
26
1.02
32
–
PN 40
–
–
–
20K
32
1.26
35
1.38
40
1 ½
PN 40
Class 150
–
–
20K
36
1.42
41
1.61
50
2
PN 40
Class 150
Table E
PN 16
10K
48
1.89
52
2.05
65
–
PN 16
–
–
–
10K
63
2.48
67
2.64
80
3
PN 16
Class 150
–
–
10K
75
2.95
80
3.15
100
4
PN 16
Class 150
–
–
10K
101
3.98
104
4.09
125
–
PN 16
–
–
–
10K
126
4.96
129
5.08
150
6
PN 16
Class 150
–
–
10K
154
6.06
156
6.14
200
8
PN 10
Class 150
–
–
10K
201
7.91
202
7.95
Materials
Transmitter housing
• Order code for "Housing", option
C
: aluminum coating AlSi10Mg
• Window material: glass
Transmitter cable entries
Order code for "Housing", option C "GT20 two-chamber, aluminum coating"
Electrical connection
Type of protection
Material
Cable gland M20 × 1.5
• Non-Ex
• Ex ia
• Ex ic
Plastic
• Ex nA
• Ex tb
Nickel-plated brass
Thread G ½"
via adapter
For non-Ex and Ex
(except for CSA Ex d/XP)
Nickel-plated brass
Thread NPT ½"
via adapter
For non-Ex and Ex
Sensor housing
Aluminum coating AlSi10Mg
Measuring tubes
Stainless steel 1.4301/304 or 1.4306/304L; for flanges made of carbon steel with Al/Zn protective coating
Содержание Proline Promag P 200