Proline Promag H 300
Hauser
37
2.5
[%]
2.0
1.5
1.0
0.5
0
0.2 %
0.5 %
0
1
2
4
6
8
10 [m/s]
v
5
10
15
20
25
30
32 [ft/s]
0
A0028974
17
Maximum measured error in % o.r.
Temperature
±3 °C (±5.4 °F)
Electrical conductivity
Max. measured error not specified.
Accuracy of outputs
The outputs have the following base accuracy specifications.
Current output
Accuracy
±5 µA
Pulse/frequency output
o.r. = of reading
Accuracy
Max. ±50 ppm o.r. (across the entire ambient temperature range)
Repeatability
o.r. = of reading
Volume flow
Max. ±0.1 % o.r. ± 0.5 mm/s (0.02 in/s)
Temperature
±0.5 °C (±0.9 °F)
Electrical conductivity
• Max. ±5 % o.r.
• Max. ±1 % o.r. for DN 15 to 150 in conjunction with stainless steel process connections, 1.4404
(F316L)
Temperature measurement
response time
T
90
< 15 s
Influence of ambient
temperature
Current output
o.r. = of reading
Temperature coefficient
Typically 1 μA/°C
Pulse/frequency output
Temperature coefficient
No additional effect. Included in accuracy.