Length of connecting cable
Note the following when mounting the remote version:
• Fix cable run or lay in armored conduit.
!
Note!
Cable movements can falsify the measuring signal especially in the case of low fluid conductivities.
• Route the cable well clear of electrical machines and switching elements.
• If necessary, establish potential equalization between the sensor and transmitter.
• The permitted cable length L
max
is determined by the fluid conductivity. A minimum conductivity of
20
μ
S/cm is needed for all demineralized water.