Proline Promag 50D
Hauser
7
Electrical connection,
terminal assignment
Electrical connection, remote
version
a0010882
Connecting the remote version
a
Wall-mount housing connection compartment
b
Sensor connection housing
c
Signal cable
d
Coil current cable
n.c.
Not connected, insulated cable shields
Cable colors/numbers for terminals:
– 5/6 = brown
– 7/8 = white
– 4 = green
– 41 = 1 / 42 = 2
Supply voltage (power supply)
HART, PROFIBUS DP
• 85 to 260 V AC, 45 to 65 Hz
• 20 to 55 V AC, 45 to 65 Hz
• 16 to 62 V DC
PROFIBUS PA
• Non-Ex: 9 to 32 V DC
• Ex i: 9 to 24 V DC
• Ex d: 9 to 32 V DC
Order version
Terminal No.
20
(+)
21
(–)
22
(+)
23
(–)
24
(+)
25
(–)
26
(+)
27
(–)
1
(L1/L+)
2
(N/L–)
50***-
***********W
–
–
–
Current output
HART
Power supply
50***-
***********A
–
–
Frequency
output
Current output
HART
Power supply
50***-
***********D
Status input
Status output
Frequency
output
Current output
HART
Power supply
50***-
***********H
–
–
–
PROFIBUS
PA
Power supply
50***-
***********J
–
–
+5 V (external
termination)
PROFIBUS
DP
Power supply
Functional values
See
"Output signal"
See "Supply voltage"
E1
E2
GND
E
S1
E1
E2
S2
GND
E
S
5
7
4 37
42 41
42 41
6
5
7
8
4 37 36
2
1
n.c.
n.c.
d
c
c
c
d
d
a
b