Proline Cubemass C 500
Hauser
61
Dependency of ambient temperature on medium temperature
T
a
T
m
B
A
A0031121
28
Exemplary representation, values in the table below.
T
a
Ambient temperature
T
m
Medium temperature
A
Maximum permitted medium temperature T
m
at T
a max
= 60 °C (140 °F); higher medium temperatures T
m
require a reduced ambient temperature T
a
B
Maximum permitted ambient temperature T
a
for the maximum specified medium temperature T
m
of the
sensor
Values for devices used in the hazardous area:
Separate Ex documentation (XA) for the device → 107.
Not insulated
Insulated
A
B
A
B
Version
T
a
T
m
T
a
T
m
T
a
T
m
T
a
T
m
Cubemass C 500 – digital
60 °C (140 °F)
205 °C (401 °F)
–
–
60 °C (140 °F)
90 °C (194 °F)
25 °C (77 °F)
205 °C (401 °F)
Cubemass C 500
60 °C (140 °F)
205 °C (401 °F)
–
–
60 °C (140 °F)
160 °C (320 °F)
55 °C (131 °F)
205 °C (401 °F)
Seals
For mounting sets with screwed-on connections:
• Viton: –15 to +200 °C (–5 to +392 °F)
• EPDM: –40 to +160 °C (–40 to +320 °F)
• Silicon: –60 to +200 °C (–76 to +392 °F)
• Kalrez: –20 to +275 °C (–4 to +527 °F)
Density
0 to 5
000 kg/m
3
(0 to 312 lb/cf)
Pressure-temperature
ratings
The following pressure/temperature diagrams apply to all pressure-bearing parts of the device and
not just the process connection. The diagrams show the maximum permissible medium pressure
depending on the specific medium temperature.
Flange connection according to EN 1092-1 (DIN 2501)