Proline Cubemass C 500
Hauser
37
HART input
2
4...20 mA
4
1
2
3
3
6
5
A0028763
4
Connection example for HART input with a common negative (passive)
1
Automation system with HART output (e.g. PLC)
2
Active barrier for power supply (e.g. RN221N)
3
Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable
specifications
4
Analog display unit: observe maximum load
5
Pressure transmitter (e.g. Cerabar M, Cerabar S): see requirements
6
Transmitter
PROFIBUS PA
2
1
3
4
7
8
6
6
6
6
5
6
6
5
A0028768
5
Connection example for PROFIBUS PA
1
Control system (e.g. PLC)
2
PROFIBUS PA segment coupler
3
Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable
specifications
4
T-box
5
Measuring device
6
Local grounding
7
Bus terminator
8
Potential matching line