Electrical connection
Flowmeter Proline 10 Modbus RS485
16
Hauser
A0041354
The cable must be in the tab for strain
relief.
7. Let the display module hang down.
A0041356
8. Remove dummy plug if present.
NOTICE
If the sealing ring is missing, the housing is
not sealed tight!
Damage to the device.
‣
Do not remove the sealing ring from the
cable entry.
9. Feed the power supply cable and signal
cable through the corresponding cable
entry.
10
(0.4
)
mm
in
A0041357
10. Strip the cable and cable ends.
11. Fit ferrules over the strands and press in
place.
A0041358
The terminal assignment is documented
on an adhesive label.
12. Connect the protective ground (PE) to
the inner ground terminal.
13. Connect the power supply cable and
signal cable as per the terminal
assignment.
14. Connect the cable shields to the inner
ground terminal.
15. Tighten the cable glands.
16. Follow the sequence in the reverse order
to reassemble.