Operation
LPGmass Modbus RS485
56
Hauser
Navigation
"Diagnostics" menu → Measured values → Totalizer
‣
Totalizer
Totalizer value 1 to n
Totalizer overflow 1 to n
Parameter overview with brief description
Parameter
Prerequisite
Description
User interface
Totalizer value
One of the following options is selected
in the
Assign process variable
submenu:
• Volume flow
• Mass flow
• Corrected volume flow
Displays the current totalizer counter
value.
Signed floating-point
number
Totalizer overflow
One of the following options is selected
in the
Assign process variable
submenu:
• Volume flow
• Mass flow
• Corrected volume flow
Displays the current totalizer overflow.
Integer with sign
11.4 Adapting the measuring device to the process
conditions
The following are available for this purpose:
• Basic settings using the
Setup
• Advanced settings using the
Advanced setup
11.5 Performing a totalizer reset
The totalizers are reset in the
Operation
submenu:
• Control Totalizer
• Reset all totalizers
Navigation
"Operation" menu → Totalizer handling
‣
Totalizer handling
Control Totalizer 1 to n
Preset value 1 to n
Reset all totalizers