Liquiline System CA80AL
Product description
Hauser
13
3.3.2
Terminal diagram
The unique terminal name is derived from:
Slot no. : Port no. : Terminal
Example, NO contact of a relay
Device with 4 inputs for digital sensors, 4 current outputs and 4 relays
• Base module BASE2-E (contains 2 sensor inputs, 2 current outputs)
• 2DS module (2 sensor inputs)
• 2AO module (2 current outputs)
• 4R module (4 relays)
1
2
3
4
43
42
41
Relay 1
Relay 2
Relay 3
Relay 4
Slot
Slot 4
Port 1 Pin 41
BASE2-E
2DS
4R
2AO
43
42
41
43
42
41
43
42
41
43
42
41
A0039621
12
Creating a terminal diagram using the example of the NO contact (terminal 41) of a relay
Содержание Liquiline System CA80AL
Страница 2: ......
Страница 117: ...Liquiline System CA80AL Operation Endress Hauser 117 5 Connect the valve or pump ...
Страница 175: ......
Страница 176: ...www addresses endress com ...