Prosonic M
8 Function group "output" (06), - "profibus param." (06), PROFIBUS-PA only
Hauser
49
8.11
Function "simulation" (065)
If necessary, linearisation, the output signal and the current output can be tested with
the simulation function. You have the following simulation options:
Selection:
•
sim. off
•
sim. level
•
sim. volume
•
sim. current (HART only)
sim. off
Simulation is switched off.
sim. level
Enter the level value in "
simulation value
"
(066)
.
The functions
•
measured value (000)
•
measured level (0A6)
•
output current" (067) - only with HART instruments!
follow the entered values.
sim. volume
Enter the volume value in "
simulation value
"
(066)
.
The functions
•
measured value (000)
•
output current" (067) - only with HART instruments!
follow the entered values.
sim. current (HART only)
Enter the current value in "
simulation value
"
(066)
.
The function
•
output current" (067) - only with HART instruments!
follows the entered values.