background image

Contact 1.800.762.1142 for assistance.

Do not return to place of purchase.

®

Owner’s manual: model 235000 outdoor patio heater

17

Troubleshooting

If the problem is:

And this condition exists:

Then do this

Pilot won’t light

Note: Heater operates at reduced efficiency below 40ºF 
(5ºC).

Tank valve is closed
Blockage in orifice or pilot tube
Air in gas line

Low gas pressure with tank valve fully open 
Igniter fails

Open valve
Clean or replace orifice or pilot tube
Open gas line and bleed it (pressing control 
knob in) for not more than 1 - 2 minutes or 
until you smell gas
Turn tank valve OFF and replace tank 
Use match to light pilot; obtain new igniter 
and replace

Pilot won’t stay lit

Dirt built up around pilot
Connection between gas valve and pilot 
assembly is loose
Thermocouple is not operating correctly

Clean dirt from around pilot
Tighten connection and perform leak check
Replace thermocouple

Burner won’t light

Gas pressure is low
Blockage in orifice
Control knob is not in ON position

Turn tank valve OFF and replace tank
Clear blockage
Turn control knob to ON

Burner flame is low

Gas pressure is low
Outdoor temperature is less than 40ºF and 
tank is less than 1/4 full
Supply hose is bent or kinked
Control knob fully ON

Turn tank valve OFF and replace tan
Use a full tank 

Straighten hose
Check burner and orifices for blockage

Emitter glows uneven

Note: Bottom 1” of emitter normally does  
NOT glow.

Gas pressure is low
Base is not on a level surface
Heater is level

Turn tank valvue OFF and replace tank
Place heater on a level surface
Clean burner

Carbon build-up

Dirt or film on reflector and emitter

Clean reflector and emitter

Thick black smoke

Blockage in burner

Remove blockage and clean burner inside and 
outside

Содержание 235000

Страница 1: ...ier recinto WARNING FOR YOUR SAFETY Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operation and maintenance instructions...

Страница 2: ...tion service or maintenance can cause injury or property damage Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment WARNING California...

Страница 3: ...er 11 Step 10 Secure Gas Line 11 Step 11 Connect Gas Line to Cylinder 12 Step 12 Check for Leaks 12 Step 13 Replace Engine Access Panel 13 Step 14 Install Igniter Battery 13 Operation Before Turning G...

Страница 4: ...st be used and replacements must be those specified by the manufacturer Inspect heater before each use If a damaged part is detected do not operate until an original equipment replacement part has bee...

Страница 5: ...spiders webs or insects Inspect heater before each use Have heater inspected annually and repairs should be made by a qualified service person Check heater immediately if any of the following conditi...

Страница 6: ...10 Stainless Steel Philips Head Screw 6 B 1 Large Screw 1 4 20 x 20 Nickel Plated Philips Head Screw 2 C 6 Small Bolt 5 32 32 x 12 Stainless Steel Hex Head Bolt 5 D 12 Large Bolt 1 4 20 x 20 Nickel P...

Страница 7: ...ir assembly step Additional Requirements The following items are not included but are necessary for the proper assembly of your heater Do NOT attempt to assemble without proper tools A hex Allen wrenc...

Страница 8: ...g 7 16 wrench secure platform to legs using 6 sets of large bolts D small lock washers I and small nuts F Tighten fully Fully tighten all nuts and bolts from step 1 Step 3 Attach Weight Plate to Base...

Страница 9: ...Slide shroud cover over gas line then over platform leg assembly until bottom of shroud rests on base Step 5 Attach Small Medium Dome to Engine Set engine assembly on its top as shown at left Carefull...

Страница 10: ...cular to base Use top three setscrews to adjust post s angle as necessary Tighten all six setscrews and slide cover back down Note post must be perpendicular to base Failure to do so will adversely af...

Страница 11: ...re not properly connected Do not proceed until you have a proper connection Fully tighten the 4 screws from step 6 Step 9 Attach Top Dome to Emitter Gently lay heater on its side using one styrofoam i...

Страница 12: ...eck for Leaks Make 2 3 oz Of leak check solution by mixing one part liquid dishwashing soap and three parts water Turn cylinder valve on Check gas line control valve for leaks Spoon several drops of s...

Страница 13: ...t in emitter bottom Rotate panel down until holes line up at bottom Secure access panel in place with thumbscrew Replace control knob Step 14 Install Igniter Battery Remove battery cover cap by turnin...

Страница 14: ...specified by manufacturer Lighting Note This heater is equipped with a Pilot Light that allows for safer startups and shutdowns Pilot must be lit before Main Burner can be started Turn Cylinder Valve...

Страница 15: ...evel of heat desired When heater is ON Emitter screen will become bright red due to intense heat The color is more visible at night Burner will display tongues of blue and yellow flame These flames sh...

Страница 16: ...asoline or other flammable liquids or vapors q Heater is away from windows air intake openings sprinklers and other water sources q Heater is at least 36 clearance top and 24 clearance side combustibl...

Страница 17: ...ermocouple is not operating correctly Clean dirt from around pilot Tighten connection and perform leak check Replace thermocouple Burner won t light Gas pressure is low Blockage in orifice Control kno...

Страница 18: ...e yellow tipping of flame Heater does NOT reach the desired temperature Heater glow is excessively uneven Heater makes popping noises Spiders and insects can nest in burner or orifices This dangerous...

Страница 19: ...ea sheltered from direct contact with inclement weather such as rain sleet hail snow dust and debris If desired cover heater to protect exterior surfaces and to help prevent build up in air passages N...

Страница 20: ...or service by you or any third party or failure to perform normal and routine maintenance on the product as set out in this owner s manual In addition the Limited Warranty does not cover damage to th...

Страница 21: ...5 90 Canadian National Standard CAN1 2 23 M82 Rating Maximum 40 000 BTU hr input Heat Range Up to 20 foot diameter Fuel Liquid Propane Gas LP Cylinder Size Nominal 20 lb 5 Gallon Inlet gas supply pres...

Страница 22: ...Contact 1 800 762 1142 for assistance Do not return to place of purchase Owner s manual model 235000 outdoor patio heater 22...

Страница 23: ...Contact 1 800 762 1142 for assistance Do not return to place of purchase Owner s manual model 235000 outdoor patio heater 23...

Страница 24: ...l Sourcing LLC Winston Salem NC 27104 USA 1 800 762 1142 www bluerhino com 2006 Blue Rhino Global Sourcing LLC All Rights Reserved Endless Summer is a registered trademark of Blue Rhino Global Sourcin...

Отзывы: