background image

Out1
Out2

s

s

m

m

T

A

 OUT 
MODE

Start

Reset

Gate

EM4401

ENDA

DIGITAL TIMER

0

TERMS

  Two pieces (Green)

  Three pieces (Green)
  Indicates selected output mode number (Green)

  Indicates setpoint name in SV indicator (Green)

      7 Segment,  4 digits green  LCD indicator (

Character height

 10mm)

      Micro switch

  ( 5 ) SV  

Display

  ( 2 ) 

Output indicators

  ( 6 ) 

Input indicators

  ( 3 ) 

Output m

od

e

 

indicator

  ( 7 ) 

Key pad

  ( 4 ) 

setpoint information

  ( 1 ) PV  

Display

(1)

 

Time value

 (

in “Running Mode”

)

      

Menu and  

Paramet

er 

 

name value

 (

in “

Program

ming

 

Mode”

)

      
     

(

2

)

 

Indicates output status.

 

(

6

)

 

Signal input status indicators.

(

5

)

 

Setpoint or time value. 

(

In “Running Mode”

     

 

Paramet

e

r

 value

 (

In “

Program

ming

 

Mode”

(

3

)

 

Output mode indicator. 

(

In “Running Mode”

)

(

4

)

 Timer setpoint selection indicator. (In “Running Mode”)

(7)

 

Key pad.

      

(

8

)

 Counting direction indicator

      

Reset

Reset

TIME VALUE SETTINGS

s

s

s

s

s

s

s

s

s

s

s

s

s

s

s

s

s

s

m

m

m

m

m

m

m

m

m

m

m

m

m

m

m

m

m

m

T

T

T

T

T

T

T

T

T

T

A

A

A

 OUT 
MODE

 OUT 
MODE

 OUT 
MODE

 OUT 
MODE

 OUT 
MODE

 OUT 
MODE

 OUT 
MODE

 OUT 
MODE

 OUT 
MODE

2559

2559

2559

2559

2559

2559

2559

2559

2559

3000

3000

3100

3000

3100

3059

3500

4000

4500

1

1

1

2

2

1

1

1

1

1

0

0

0

0

0

0

0

0

0

Out2

Out2

Out2

Out2

Out2

Out2

Out2

Out2

Out2

Out1

Out1

Out1

Out1

Out1

Out1

Out1

Out1

Out1

SET

T

A

2

T

2

T

A

1

Is any key 

 is pressed for 3 

seconds?

YES

NO

After the T1 time is selected with           key, by          key is pressed and to be adjusted and selected left two digits of the T1 setpoint appears 

by flashing. T1 time setpoint can be adjusted by using         and         keys for required value. By using           key, toggles between right and 

left two digits. 

By using           key, T1A, T2 and T2A time setpoints can be selected and can be adjusted like T1 time value. 

If no key is pressed for 3 seconds, it returns to "Running Mode".

While in "Runnig Mode", by every pressing            key, T1, T1A, T2 and T2A setpoints can be selected respectively. 
Selected value is indicated by flashing. If no key is pressed for 3 seconds, it returns to "Running Mode".

T1A setpoint can be visible if Out Mode 9, A, and b is selected.

T2 setpoint can be visible if 

o.2.cn

 parameter is selected as 

t2.on

 , 

t2.oF

 or "Out Mode b" is selected.

T2A setpoint can be visible if 

o.2.cn

 parameter is selected as 

t2.on

 , 

t2.oF

 or "Out Mode 9", "Out Mode A" or 

“Out Mode b" is selected.

When changes are made in 

t1.r

 , 

t1.L

 and 

t1.H

 parameters of T1 setpoint and if T1 setpoint is not in limits, T1 will be set 

into the limits automatically.

When changes are made in 

t1A.r

 , 

t1A.L

 and 

t1A.H

 parameters of T1A setpoint and if T1A setpoint is not in limits, T1A will 

be set into the limits automatically.

When changes are made in 

t2.r

 , 

t2.L

 and 

t2.H

 parameters of T2 setpoint and if T2 setpoint is not in limits, T2 will be set 

into the limits automatically.

When changes are made in 

t2A.r

 , 

t2A.L

 and 

t2A.H

 parameters of T2A setpoint and if T2A setpoint is not in limits, T2A will 

be set into the limits automatically.

T2 and T2A set values are can be visible if   

o.2.cn

  parameter is selected as  

t2.on

 ,  

t2.oF

  or 

"Out Mode b" is selected.

RUNNING MODE

SET

0

0

TIME VALUE SETTING POSITION

      7 Segment,  4 digits green  LCD indicator (

Character height

 7mm)

2/7

EM4401-EN-01-180308

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 

Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-

TURKEY

Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:

18

ENDA

TM

Содержание EM4401 Series

Страница 1: ...ing according to DIN 43 700 Dimensions W48xH48xD87mm Weight Approx 230g After packing Enclosure Materials Self extinguishing plastics While cleaning the device solvents thinner gasoline acid etc or corrosive materials must not be used HOUSING Mo Tu We Th Fr Sa Su Out1 Out2 Out3 s s m m h Mo T A PRG OUT MODE Tu We Th Fr Sa Su h Start Reset Gate EM4401 ENDA DIGITAL TIMER 0 EM4401 EN 01 180308 SİSEL ...

Страница 2: ...s of the T1 setpoint appears by flashing T1 time setpoint can be adjusted by using and keys for required value By using key toggles between right and left two digits By using key T1A T2 and T2A time setpoints can be selected and can be adjusted like T1 time value If no key is pressed for 3 seconds it returns to Running Mode While in Runnig Mode by every pressing key T1 T1A T2 and T2A setpoints can...

Страница 3: ...tion can be done Only visible Input Type Selection nPn or PnP values can be selected Start Gate and Reset input types will be changed according to this parameter Display Brightness Selection Display brightness can be adjusted between 1 and 20 DeviceAddress ModBus Communication address can be a d j u s t a b l e b e t w e e n 1 and 247 Panel Reset Control If Off is selected the reset button not wor...

Страница 4: ... o t is selected Hold Periodically OUT1 is set to ON or OFF with every OUT2 is set to ON or OFF with every T2 time T1 time MODE 1 RESET and DELAY with PULSE START ON MODE 2 DELAY with START ON OFF MODE 3 RESET with START and DELAY with START OFF MODE 4 PERIODIC PROCESS with START PULSE Pulse output is taken about o1 o t lenght from OUT1 Pulse output is taken about from OUT2 o2 o t lenght o1 cn t1 ...

Страница 5: ...OUT2 is set ON or OFF about T2 lenght when START Input is set to ON MODE 8 SINGLE PERIOD TIMING with START ON Power Power o2 cn t2 on o2 cn t1 on o1 cn t1 on o2 cn t1 on o2 cn t2 on o1 cn t1 on o1 cn t1 oF o2 cn t1 oF o2 cn t2 oF o1 cn t1 oF o2 cn t1 oF o2 cn t2 oF Start T1 time T2 time T2A time T2 time T1A time T1 time T1A time Start Reset Out1 Out2 Out2 Out1 Out2 Out2 Out1 Out2 Out2 Out1 Out2 TI...

Страница 6: ...used OUTPUT TYPES GRAPHS 3 TIMER1 TIMER2 TIMER1 o2 cn off Out2 o2 cn P on Out2 Out2 power on Up timer is selected Down timer is selected Up timer is selected Down timer is selected If o2 cn oFF Out2 is cancelled Up timer is selected Down timer is selected NOTE 1 If Gate in put is active standby mode is switched in all Operating Mode Power Power o2 cn t2 on o2 cn t1 on if o2 cn oFF Out2 is cancelle...

Страница 7: ...mounting additional space should be allocated for cables 2 Panel thickness should be maximum 9mm 3 If there is no 100mm free space at back side of the device it would be difficult to remove it from the panel ENDA EM4401 is intended for installation within control panels Make sure that the device is used only for intended purpose The shielding must be grounded on the instrument side installation al...

Страница 8: ...0 bps 6 38400 bps 7 57600 bps Device address values for Modbus Adjustable between 1 and 247 Word 0028d 001Ch Word Word 0029d 001Dh 0030d 001Eh 1 2 Memory Map for Control Coils Parameter Number Data Type R W R W R W R W R W R W C0 C1 C2 C3 C4 C5 C15 Timer counting direction 0 Count UP 1 Count DOWN Data storage in case of power failure Permanent memory parameters 0 Storing data enabled Possible 1 St...

Страница 9: ...bus protocol has two types error communication error and operating error Reason of the communication error is data corruption in transmission Parity and CRC control should be done to prevent communication error Receiver side checks parity and CRC of the data If they are wrong the message will be ignored If format of the data is true but function doesn t perform for any reason operating error occur...

Отзывы: