SENSOR CONNECTION SAMPLES

+ 12V

GND

+ 12V

+ 12V

1

1

1

1

1

1

1

1

1

1

1

1

12

12

12

12

13

13

13

13

14

14

14

14

15

15

15

15

16

16

16

16

2

2

2

2

3

3

3

3

4

4

4

4

5

5

5

5

6

6

6

6

7

7

7

7

8

8

8

8

9

9

9

9

10

10

10

10

230V AC

 

Supply

230V AC

 

Supply 

230V AC

 Supply

230V AC

 Supply

 

Switch

Anahtar

Cable size: 1,5mm²

Cable size: 1,5mm²

Fuse

F 100 mA 

250V AC

Fuse

F 100 mA 

250V AC

Typical connections for PNP sensor type

Typical connections for NPN sensor type

PNP PROXIMITY SWITCH

NPN

 PROXIMITY SWITCH

GND

GND

Start

Start

RESET

RESET

START

START

GATE

GATE

OUT (Active level is sensor 
supply voltage)

OUT (Active level GND)

Flush

mounting

clamp

Panel

5

8

m

m

CONNECTION DIAGRAM

230V AC

or

21.6-26.4V AC 

50/60Hz 5VA

SUPPLY :

NOT

E

 :

4

8

m

m

DIMENSIONS

12

11

8

0

m

m

Connection

Cables

+

0

.6

 4

5

  

  

 m

m

 45     mm

+0.6

Panel cut-out

230V AC 

or

 24V AC

Supply

1

1

51mm

Depth

87mm

2

Not

e

 :

Logic  output  of  the  device  is  not  electrically  isolated. 
Therefore,  the  logic  output  terminals  should  not  be 
grounded  when  using  grounded  thermocouples.

1) 

Mains  supply  cords  shall  meet  the  requirements  of

 

IEC60227 

or

 IEC60245.

2)

  In  accordance  with  the  safety  regulations,  the  power 

supply switch shall bring the identification of the relevant 
instrument  and  it  should  be  easily  accessible  by  the 
operator.

Vida sıkma momenti 
0.4-0.5Nm 

For removing mounting clamps ;

Cihazın tümünde ÇİFT
YALITIM vardır.

Out1
Out2

s

s

m

m

T

A

 OUT 
MODE

Start

Reset

Gate

Em4401

ENDA

DIGITAL TIMER

0

Switch

Fuse

F 100 mA 

250V AC

Switch

Fuse

F 100 mA 

250V AC

Cable size: 1,5mm²

Cable size: 1,5mm²

-

 Push the device in direction 

1

 as 

shown in the figure.

-

 Then pull out the device in direction 

2

 .

Note :

1) 

While performing panel mounting,additional 

space should be allocated for cables.

2) 

Panel thickness should be maximum 

9mm.

3) 

If there is no

 100mm 

free space at back 

side of the device, it would be difficult to 
remove it from the panel.

ENDA  EM4401 

 is intended for installation within 

control panels.  Make sure that the device is used 
only for intended purpose. The shielding

must  be  grounded  on  the  instrument  side. 
installation,  all  of  the  cables  that  are  connected  to  the 
device must be free of electrical  power.   The device must 
be protected   against   inadmissible   humidity,   vibrations,   
severe    soiling.    Make    sure    that    the    operation 
temperature is not exceeded. All input and output lines that 
are not connected to 

  During  an 

the supply network must be laid out as 

shielded and twisted cables. These cables should not be 
close to the power cables or components. The installation 
and electrical connections must be carried out by a qualified 
staff  and  must  be  according  to  the  relevant  locally 
applicable regulations. 

Phase

Neutral

Switch

Cable size: 1,5mm²

Fuse

F 100 mA 

250V AC

Fuse should
be connected.

7

/7

EM4401-EN-01-180308

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 

Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-

TURKEY

Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:

18

ENDA

TM

E

M

44

01

-230VAC 

       

DIGITAL TIMER

INDUSTRIAL
ELECTRONICS

ENDA

SN: XXXXXXXXX

MADE IN TURKEY

SSR2 OUT

SSR1 OUT

RESET IN

START IN

GATE IN

GND

+12V 50mA

1

2

3

4

5

6

7

8

9

10

8 680407 718795

OUT1

OUT2

AC 250V 

10

A

RESISTIVE
LOAD

AC 250V 

5

A

RESISTIVE
LOAD

11

12

13

16

14

15

17

230V AC

 

50/60Hz  5VA

 

-

+

RS- 485

A

B

RS-485 COM.

8 680407 718801

E

M

44

01

-230VAC

-RS

 

       

DIGITAL TIMER

INDUSTRIAL
ELECTRONICS

ENDA

SN: XXXXXXXXX

MADE IN TURKEY

SSR2 OUT

SSR1 OUT

RESET IN

START IN

GATE IN

GND

+12V 50mA

1

2

3

4

5

6

7

8

9

10

OUT1

OUT2

AC 250V 

10

A

RESISTIVE
LOAD

AC 250V 

5

A

RESISTIVE
LOAD

11

12

13

16

14

15

17

230V AC

 

50/60Hz  5VA

 

Содержание EM4401 Series

Страница 1: ...ing according to DIN 43 700 Dimensions W48xH48xD87mm Weight Approx 230g After packing Enclosure Materials Self extinguishing plastics While cleaning the device solvents thinner gasoline acid etc or corrosive materials must not be used HOUSING Mo Tu We Th Fr Sa Su Out1 Out2 Out3 s s m m h Mo T A PRG OUT MODE Tu We Th Fr Sa Su h Start Reset Gate EM4401 ENDA DIGITAL TIMER 0 EM4401 EN 01 180308 SİSEL ...

Страница 2: ...s of the T1 setpoint appears by flashing T1 time setpoint can be adjusted by using and keys for required value By using key toggles between right and left two digits By using key T1A T2 and T2A time setpoints can be selected and can be adjusted like T1 time value If no key is pressed for 3 seconds it returns to Running Mode While in Runnig Mode by every pressing key T1 T1A T2 and T2A setpoints can...

Страница 3: ...tion can be done Only visible Input Type Selection nPn or PnP values can be selected Start Gate and Reset input types will be changed according to this parameter Display Brightness Selection Display brightness can be adjusted between 1 and 20 DeviceAddress ModBus Communication address can be a d j u s t a b l e b e t w e e n 1 and 247 Panel Reset Control If Off is selected the reset button not wor...

Страница 4: ... o t is selected Hold Periodically OUT1 is set to ON or OFF with every OUT2 is set to ON or OFF with every T2 time T1 time MODE 1 RESET and DELAY with PULSE START ON MODE 2 DELAY with START ON OFF MODE 3 RESET with START and DELAY with START OFF MODE 4 PERIODIC PROCESS with START PULSE Pulse output is taken about o1 o t lenght from OUT1 Pulse output is taken about from OUT2 o2 o t lenght o1 cn t1 ...

Страница 5: ...OUT2 is set ON or OFF about T2 lenght when START Input is set to ON MODE 8 SINGLE PERIOD TIMING with START ON Power Power o2 cn t2 on o2 cn t1 on o1 cn t1 on o2 cn t1 on o2 cn t2 on o1 cn t1 on o1 cn t1 oF o2 cn t1 oF o2 cn t2 oF o1 cn t1 oF o2 cn t1 oF o2 cn t2 oF Start T1 time T2 time T2A time T2 time T1A time T1 time T1A time Start Reset Out1 Out2 Out2 Out1 Out2 Out2 Out1 Out2 Out2 Out1 Out2 TI...

Страница 6: ...used OUTPUT TYPES GRAPHS 3 TIMER1 TIMER2 TIMER1 o2 cn off Out2 o2 cn P on Out2 Out2 power on Up timer is selected Down timer is selected Up timer is selected Down timer is selected If o2 cn oFF Out2 is cancelled Up timer is selected Down timer is selected NOTE 1 If Gate in put is active standby mode is switched in all Operating Mode Power Power o2 cn t2 on o2 cn t1 on if o2 cn oFF Out2 is cancelle...

Страница 7: ...mounting additional space should be allocated for cables 2 Panel thickness should be maximum 9mm 3 If there is no 100mm free space at back side of the device it would be difficult to remove it from the panel ENDA EM4401 is intended for installation within control panels Make sure that the device is used only for intended purpose The shielding must be grounded on the instrument side installation al...

Страница 8: ...0 bps 6 38400 bps 7 57600 bps Device address values for Modbus Adjustable between 1 and 247 Word 0028d 001Ch Word Word 0029d 001Dh 0030d 001Eh 1 2 Memory Map for Control Coils Parameter Number Data Type R W R W R W R W R W R W C0 C1 C2 C3 C4 C5 C15 Timer counting direction 0 Count UP 1 Count DOWN Data storage in case of power failure Permanent memory parameters 0 Storing data enabled Possible 1 St...

Страница 9: ...bus protocol has two types error communication error and operating error Reason of the communication error is data corruption in transmission Parity and CRC control should be done to prevent communication error Receiver side checks parity and CRC of the data If they are wrong the message will be ignored If format of the data is true but function doesn t perform for any reason operating error occur...

Отзывы: