Power
Power
o2.cn.
=
t2.on
o2.cn.
=
t1.on
o1.cn
=
t1.on
o2.cn
=
t1.on
o2.cn
=
t2.on
o1.cn
=
t1.on
o1.cn
=
t1.oF
o2.cn
=
t1.oF
o2.cn
=
t2.oF
o1.cn
=
t1.oF
o2.cn.
=
t1.oF.
o2.cn.
=
t2.oF.
Start
T1 time
T1 time
T2 time
T2A time
T2-x
T1A time
T1A time
T1 time
T1 time
T1-x
T1-x
Start
Reset
Out1
Out2
Out2
Out1
Out2
Out2
Out1
Out2
Out2
Out1
Out2
Out2
T1
T1A
T1A
T1
0
0
0
0
T2
T2A
T2A
T2
MODE A
ON-OFF TIME PERIODIC PROCESS
with CONSTANT START and
RESET with START OFF
DETAILED EXPLANATION
FAST EXPLANATION
x = Unknown time
Power
Power
Power
o2.cn.
=
t2.on
ATTENTION! In order to choose this mode ,
.
parameter must be setted to
or
.
o2.cn
t2.on
t2.of
o1.cn
=
t1.on
o2.cn
=
t2.on
o1.cn
=
t1.on
o1.cn
=
t1.oF
o2.cn
=
t2.oF
o1.cn
=
t1.oF
o2.cn.
=
t2.oF.
Start
Start
Reset
Out1
Out2
Out2
Out1
Out1
Out2
Out1
Out2
Out2
T1
T1
T2
T2
T1A
T1A
T2A
T2A
0
0
MODE B
ON-OFF TIME
DOUBLE CONTACT
DOUBLE PERIODIC
PROCESS with
START PULSE
T1
time
T1
time
T1A
time
T1A
time
T2
time
T2
time
T2A
time
NOTE 2 : If
o2.cn
parameter is set to
P.on
, then Out2 output is activated and remains until power down.
In this setup , Out2 output is used in order to observe power state of timer. Other Out2 functions can not be used.
OUTPUT TYPES GRAPHS - 3
T
IM
E
R
1
T
IM
E
R
2
T
IM
E
R
1
o2.cn
=
off
Out2
o2.cn
=
P.on
Out2
Out2 power on
Up timer is selected
Down timer is selected
Up timer is selected
Down timer is selected
If
o2.cn.
=
oFF
, Out2 is cancelled
Up timer is selected
Down timer is selected
NOTE 1 : If Gate in put is active , standby mode is switched in all ‘‘Operating Mode’’.
Power
Power
o2.cn.
=
t2.on
o2.cn.
=
t1.on
if
o2.cn.
=
oFF
Out2 is cancelled
o1.cn
=
t1.on
o1.cn
=
t1.on
o2.cn
=
t1.on
o2.cn
=
t2.on
o1.cn
=
t1.oF
o1.cn
=
t1.oF
o2.cn
=
t1.oF
o2.cn
=
t2.oF
o2.cn.
=
t1.oF.
o2.cn.
=
t2.oF.
Start
Start
T1 = a + b
T1 = a + b
T2 = a + c
Reset
Out1
Out1
Out2
Out2
Out2
Out2
Out1
Out1
Out2
Out2
Out2
Out2
T1
T1
0
0
0
0
T2
T2
If
o1.o.t
or
o2.o.t
is selected Hold ,output
is generated constantly
until ON START Input or
RESET Input is taken
from OUT1 or OUT2.
Up timer is selected
Up timer is selected
Down timer is selected
Down timer is selected
MODE C
RESET with START OFF
after TIMING with start
a
a
a
b
d
d
d
b
c
delay
delay
delay
T
IM
E
R
2
T
IM
E
R
1
o2.cn
=
off
Out2
o2.cn
=
P.on
Out2
Out2 power on
Pulse output is taken
about
o1.o.t
lenght
from OUT1.
Pulse output is taken
about
from OUT2.
o2.o.t
lenght
6
/7