Features

• One button sets time of day, another button sets watering

start time

• Two rotary dials for setting the watering interval and

watering duration.

• Battery operated (three AA), not included.
• Ten watering interval options (once, 2 hr, 4 hr, 8 hr, 12 hr, daily,

2nd day, 3rd day, 4th day, 7th day).

• Ten watering duration options (on, OFF, 2 min, 5 min, 

10 min, 15 min, 30 min, 60 min, 90 min, 120 min).

• Manual watering without interrupting the watering interval.
• Weather resistant design.
• Dependable valve design.
• Low power consumtion soleniod.

Battery installation

Note:

Orbit recommends the use of Duracell

®

or Energizer

®

brand 

AA alkaline batteries for optimum timer performance.

(see figure 1).

1. Remove the timer cover.
2. Pull the battery compartment out of the timer.
3. Install three AA alkaline batteries. Refer to the battery 

compartment for the correct orientation of the batteries, 
(see figure 1).

4. Place the battery compartment back in the timer. 
• Three fresh AA alkaline batteries should last for an entire

watering season. When the battery voltage is below a safe
operating voltage the valve will not open. The batteries
should be replaced with new ones when this occurs.

5. Replace the timer cover to protect the timer from moisture

and debris.

Figure 1

Set the time of day and watering start time 

• Press the Set Time button, holding it down for 2 seconds. The

digital readout will cycle through a.m. and p.m. time settings.
Release the Set Time Button just before the correct time of
day is reached. Tap the button to advance the time in 1
minute increments until correct time is reached.

• Press the Set Start button, holding it down for 2 seconds. The

digital readout will cycle through a.m. and p.m. time settings.
Release the Set Start button just before the desired watering
start time is reached. Tap the button to advance the time in 1
minute increments until desired start time is reached.

Note:

The timer valve will close when making entries using the Set
Time and Set Start buttons. Set Time and Set Start settings are
accepted by the timer 5 seconds after buttons are released,
except at the ON setting.

Set the watering start interval

Turn the Start Interval dial to the desired watering interval.
(see figure 2).

Note:

All Start Interval settings begin timing at the Set Start time
shown on the digital readout.

The Start Interval dial has ten possible settings:

• Once – the valve will open once for the amount of time on

the Duration dial and then remains inactive until the Start
Interval dial is rotated to another setting.

• 2 hr – the water will come on every two hours.
• 4 hr – the water will come on every four hours.
• 8 hr – the water will come on every eight hours.
• 12 hr – the water will come on every twelve hours.
• Daily – the water will come on once every day.
• 2nd day – the water will come on every other day.

Environmental Conditions

Working Temperature: 32 to 122°F
Storage Temperature: -14 to 140°F

Conditions environnementales

Température propre au fonctionnement : 0 à 50°C (32 à 122°F)
Température d’entreposage : -10 à 60°C (-14 à 140°F)

Condiciones ambientales

Temperatura de trabajo: 0 a 50°C (32 a 122°F)
Temperatura de almacenamiento: -10 a 60°C (-14 a 140°F)

HOSE FAUCET

HOSE WASHER

BRASS 

CONNECTOR

AUTOMATIC HOSE

FAUCET VALVE

COVER

TIMER

Installation and User’s Guide

Dual Dial Hose Timer with Electronic Display 
Model 62040, 62055 and 91050

Minuterie numérique
d’arrossage à deux boutons,

modèles 62040, 62055 et 91050

Timer Digital de 2 cuadrantes 
para riego,

modelos 62040, 62055 y 91050

Orbit

®

Irrigation Products, Inc.

845 North Overland Rd. 
North Salt Lake, Utah 84054

PN 62040-24 Rev B

© 2005 Orbit

®

Irrigation Products, Inc.

All rights reserved. All trade names 
are registered trademarks of respective 
manufacturers listed.

http://waterheatertimer.org/Woods-timers-and-manuals.html#sprinkler

Содержание Sunmate 62040

Страница 1: ... cycle through a m and p m time settings Release the Set Start button just before the desired watering start time is reached Tap the button to advance the time in 1 minute increments until desired start time is reached Note The timer valve will close when making entries using the Set Time and Set Start buttons Set Time and Set Start settings are accepted by the timer 5 seconds after buttons are re...

Страница 2: ...lly Note Manual watering overrides the Set Start time allowing imme diate watering To change the watering duration while the valve is open simply rotate the dial to the new duration The valve will remain open for the duration shown on the Duration dial regardless of how long the valve had been open prior to the change Watering once Turn the Start Interval dial to the ONCE setting and turn the Dura...

Страница 3: ...nce toutes les quatre heures 8 hr l arrosage commence toutes les huit heures AVERTISSEMENT Le raccord pivotant de la minuterie au robi net de tuyau et le raccord vissé de la minuterie au pivot du tuyau sont conçus pour supporter des ajustements latéraux normaux du tuyau Il convient d éviter les mouvements abrupts ou énergiques du tuyau Installation des piles REMARQUE Pour une performance optimale ...

Страница 4: ...églage de Set Time sur l affichage numérique sauf lorsque le bouton de durée Duration est en position ON Par le réglage de Set Start sur l affichage numérique sauf lorsque le bouton de durée Duration est en position ON En tournant le bouton de durée Duration sur la position OFF Arrosage manuel Tournez le bouton de durée Duration en position ON La valve s ouvre et reste ouverte jusqu à ce que le bo...

Страница 5: ...drá una vez todos los días 2º día el agua saldrá día por medio 3º día el agua saldrá cada tres días 4º día el agua saldrá cada cuatro días 7º día el agua saldrá una vez por semana Illustration 2 Características Un botón fija la hora del día otro botón fija la hora de inicio del riego Dos cuadrantes giratorios para fijar el intervalo y la duración del riego Operación con baterías tres baterías alca...

Страница 6: ...brirá mientras el cuadrante esté en esta posición 2 min 5 min 10 min 30 min 60 min 90 min 120 min el agua saldrá automáticamente a los intervalos que muestra el cuadrante del Intervalo de inicio y seguirá saliendo durante el tiempo seleccionado antes de apagarse automáticamente Para cambiar la duración del riego mientras la válvula está abierta simplemente gire el cuadrante a la nueva duración La ...

Страница 7: ...ED NOT USED NOT USED BLACK NOT USED NOT USED NOT USED 07SUM002524 62040 24 RB QXD DOUBLE SIDED PAGES PLEASE 046878 5 5 SM 07SUM002524 12 20 06 XX 6 1 XX 9 XX ORBIT 07SUM002524 62040 24 rB qxd 12 28 06 12 45 PM Page 7 ...

Отзывы: