12
http://www.end.de
DG2D - 07/2016
Device variants
4.3
Device variants
The pressure actuated valves DG2D will be delivered in various variants.
The following table explains the composition of the article number to you. These article numbers
will be seen on the name plate:
For example:
DG2D3116025/OS
Pressure actuated valve, Stainless steel / PTFE, normally close with the
flow direction, Stainless steel cylinder, G 1", with optical position indicator
3. Digit
Ways
2. Digit
Connection
1. Digit
Product
D
= Pressure actuated
valve
G
= B.S.P. thread
DIN ISO 228 T1
A
= Welded connection
DIN 3293
L
= Welded connection
ISO 4200
M
= Welded connection
DIN 11850-R2
F
= flanges acc. to DIN
2531 / 2533 / 2545
2
= 2/2-ways
3
= 3/2-ways
6. Digit
Seals material
seat / stem
1
= brass
2
= bronze
3
= stainless steel
4
= Carbon steel
5
= GG (grey cast iron)
6
= GGG (ductile iron)
7
= Light alloy
8
= Plastic
4. Digit
Operation
D
= direct acting
5. Digit
Body material
1
= PTFE / PTFE
2
= PTFE / NBR
3
= PTFE / FKM
4
= PTFE / EPDM
5
= NBR / PTFE
6
= NBR / NBR
7
= FKM / FKM
8
= FKM / PTFE
brass cylinder
0
= Ø 32 mm
1
= Ø 50 mm
2
= Ø 80 mm
3
= Ø 125 mm
(aluminium alloy)
4
= Ø 100 mm
stainless steel cylinder
5
= Ø 50 mm
6
= Ø 80 mm
7
= Ø 125 mm
(aluminium alloy)
8
= Ø 100 mm
9
= Ø 32 mm
threaded
flanged and welded
connection
connection
006
=
G
⅛
008
=
G
¼
010
=
G
⅜
015
=
G
½
DN 15
020
=
G
¾
DN 20
025
=
G 1
DN 25
032
=
G 1
¼
DN 32
040
=
G
1
½
DN 40
050
=
G 2
DN 50
065
=
G
2
½
DN 65
080
=
G
3
DN 80
100
=
G 4
DN 100
125
= others sizes
DN 125
150
= on request
DN 150
ES
= electric / mechanic position indicator
FL
= flanged connection PN 16
HB
= stroke stop
HN
= manual override
HY
= hygienic version
HO
= stroke stop and optical position indicator
7. Digit
Operation
8. Digit
Piston- Ø
9. - 11. Digit
Connection
for 2/2-way-version:
1
= Normally close
with the flow
direction
2
= Normally close
against the flow
direction
3
= Normally open
against flow
direction
4
= Double acting
for 3/2-way-version:
1
= split function
2
= mixing function
12. - 20. Digit
Options
NI
= inductive proximity limit switch
OF
= free of oil and grease
OG
= without valve body
OS
= optical position indicator
NS
= contactless position indicator (Reed- contact)
V
= for vacuum
VD
= for vacuum and pressure
Содержание DA2D3
Страница 38: ...38 http www end de DG2D 07 2016 ...
Страница 39: ......