STEP 3
By tightening the inner radial screw (approx. 2 Nm / 283 oz-in) with a 2.5 mm hex driver the encoder shaft will be clamped to the draw wire 
unit and is secured from slipping.

STEP 4
By tightening the outer radial screw (approx. 2 Nm / 283 oz-in) with a 2.5 mm hex driver the encoder housing will be clamped to the draw wire 
housing and is secured from twisting. The complete assembly is now ready to be mounted at the desired location.

Содержание TB-544

Страница 1: ...wire exit downwards Otherwise water will gather inside the housing which leads to corrosion Where applicable use the bottom wire exit option READ FIRST Proper Handling of the Wire Unpacking Your Draw Wire Unit Carefully lift the device out of the box by the housing Do not pull the wire After unpacking the device check it for any visible damage as a result of rough handling during shipment Check th...

Страница 2: ... wire more than the specified measurement range as this might destroy the draw wire unit and void the warranty Use a deflection pulley if required Avoid guiding the wire over edges or corners The maximum deviation off the exit axis is 3 Avoid extracting the wire at an angle off the exit axis since the service life of the draw wire unit will be greatly reduced If it is not possible to keep the wire...

Страница 3: ...led or damaged A cut or loose wire may lead to injuries or a damage to the draw wire unit or encoder Mounting of the Draw Wire Unit Please start by mounting the encoder to the LCX draw wire unit A description is given on the following pages Next mount the draw wire unit at the desired location by using the mounting holes Do not extract the wire or attach the wire to the measuring target until the ...

Страница 4: ...ng of the encoder by the customer A detailed description of the mounting procedure is shown in the following pictures IMPORTANT Encoders suitable for use with the LCX units must have clamping flange with 36 mm diameter a shaft diameter of 10 mm and a shaft length between 10 and 20 mm NOTE All non metric measurements in this document are for reference only Mounting by Clamping Flange STEP 1 Start b...

Страница 5: ...crew approx 2 Nm 283 oz in with a 2 5 mm hex driver the encoder shaft will be clamped to the draw wire unit and is secured from slipping STEP 4 By tightening the outer radial screw approx 2 Nm 283 oz in with a 2 5 mm hex driver the encoder housing will be clamped to the draw wire housing and is secured from twisting The complete assembly is now ready to be mounted at the desired location ...

Страница 6: ...ription of this EASY Clamp Mechanism in the next section IMPORTANT All incremental and absolute encoders are suitable that have a clamping flange with 36 mm diameter a shaft diameter of 10 mm and a shaft length between 10 and 20 mm Easy Clamp Mechanism STEP 1 Start by sliding the included coupling 1 onto the shaft of the encoder and tighten the set screw 1 Nm 141 oz in with a 2 mm hex driver Pleas...

Страница 7: ...les encoder com Page 7 10 TB 544 LCX DRAW WIRE INSTALLATION GUIDE 2020 Encoder Products CompanyTB 544 REV 11 12 2020 STEP 2 To mount the encoder into the easy clamp flange slip the cylinder bolt 1 of the coupling into the spring 2 1 2 ...

Страница 8: ...WIRE INSTALLATION GUIDE 2020 Encoder Products CompanyTB 544 REV 11 12 2020 STEP 3 Use a 3 mm hex driver to tighten the radial screw 1 5 Nm 212 oz in The encoder will be clamped and secured from twisting The draw wire assembly is now ready to be mounted at the desired location ...

Страница 9: ...ly is usually installed by using the regular mounting plate By disassembling the mounting plate there are 2 x M4 threads in the draw wire housing for alternative installation Mounting for sideways bottom wire exit option 2 bottom wire exit option 3 Draw wire units with option 2 or option 3 wire exits have a modified base plate 60 17 25 2 x M4 17 25 2 x M4 100 LCX80 LCX80 LCX120 LCX120 Option 2 Opt...

Страница 10: ...uts have a M6 thread Two up to 20 m measurement range or four more than 25 m measurement range T slot nuts are included in the package Step 2 Mounting via angle clamp brackets The angle clamp brackets feature a bore for M6 screws to fix it on a plate slab or a profile Two up to 20 m measurement range or four more than 25 m measurement range angle clamp brackets are included in the delivery 17 7 5 ...

Отзывы: