![Encoder TB-544 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/encoder/tb-544/tb-544_installation-manual_2405989006.webp)
1-800-366-5412 | www.encoder.com | [email protected]
Page 6/10
TB-544
LCX DRAW WIRE INSTALLATION GUIDE
© 2020 Encoder Products Company TB-544, REV. 11/12/2020
Mounting an Encoder to LCX135 (10 m and above)
The LCX135 with measurement ranges 10 m or greater is available for an encoder to be mounted by the customer. You will find a detailed 3
step description of this EASY-Clamp-Mechanism in the next section.
IMPORTANT:
All incremental and absolute encoders are suitable that have a clamping flange with 36 mm diameter; a shaft diameter of 10 mm;
and a shaft length between 10 and 20 mm.
Easy-Clamp-Mechanism
STEP 1
Start by sliding the included coupling (1) onto the shaft of the encoder and tighten the set screw (1 Nm / 141 oz-in) with a 2 mm hex driver.
Please pay attention that the dimension between contact surface of the encoder and the end of the cylinder bolt is 35 mm.
36
Ø
10
L = 10...20
3
6
Ø
(1)
35