1-800-366-5412 | www.encoder.com | [email protected]
Page 4/10
TB-544
LCX DRAW WIRE INSTALLATION GUIDE
© 2020 Encoder Products Company TB-544, REV. 11/12/2020
Mounting an Encoder
Mounting an Encoder to the LCX80, LCX120, and LCX135 (up to 8 m) draw wire units
The LCX Series draw wire units allow a fast and easy mounting of the encoder by the customer. A detailed description of the mounting
procedure is shown in the following pictures.
IMPORTANT:
Encoders suitable for use with the LCX units must have: clamping flange with 36 mm diameter; a shaft diameter of 10 mm; and
a shaft length between 10 and 20 mm.
NOTE:
All non-metric measurements in this document are for reference only.
Mounting by Clamping Flange
STEP 1
Start by inserting the encoder into the clamping flange.
STEP 2
The encoder is now connected to the clamping flange.