background image

Users’ Manual 

 

ESM-12S Digital seepage monitoring system 

  

  

 

Page

 | 

25

 

8  CONNECTING TO NODE & GATEWAY 

Wireless sensor network are becoming vital in civil engineering and geotechnical field. Encardio-rite offers 
an innovative wireless solution that allows real-time monitoring of geotechnical and structural sensors in 
challenging construction projects, with reliable data transfer over long distances without any delay. 
The digital sensors (with SDI-12 or Modbus (RS-485) output ) are interfaced with the long range, low power 
wireless network through model EWN-01D 

digital node 

that allows sensors to send recorded data to the 

model EWG-01 

gateway

 with over 99% reliability, eliminating the need for running lengthy cables. The 

gateway then uploads all the collected sensor data to the central/cloud server. 

The digital node consists of a radio-transceiver with an antenna, a microcontroller, sensor module that 
reads the sensor; a wireless communication module that transmits the digital data to the gateway, and a 
processor that controls the two modules. It is a highly reliable integrated system, which is  capable of 
collecting data from

 

digital  sensors and reporting measurements through  RF  wireless communication 

network to the gateway.  
The node is housed in a rugged enclosure designed for use in harsh environments with wide temperature 
tolerance with resistance to moisture and humidity. 
A cloud-hosted data management and configuration software can be used to manage the network. The 
configuration can be done with an easy to use smartphone application that comes free with the system.  
The system can generate automatic reports and provide automated alerts over SMS or email for any 
reading crossing the pre-defined alert levels. 

8.1  Sensors with SDI-12 output option 

The sensor with SDI-12 output will be connected to the “SDI” port (right-most) of the digital node as shown 
in figure below.  
 

Figure 10-1 Digital Node and Gateway

 

Содержание ESM-12S

Страница 1: ...through ingenuity USERS MANUAL ENCARDIO RITE ELECTRONICS PVT LTD A 7 Industrial Estate Talkatora Road Lucknow UP 226011 India P 91 522 2661039 42 Email geotech encardio com www encardio com Internati...

Страница 2: ...of moisture trap assembly and junction box 9 4 4 Installation of datalogger 10 5 CONNECTING EPS 12S TO ESDL 30 DATALOGGER 11 5 1 Wiring details for sensors with SDI 12 output 11 5 2 Wiring details for...

Страница 3: ...g ESDL 30 datalogger is a compact datalogger that can be mounted easily near the sensor or in a control room in close vicinity The system can also be directly connected to RF nodes and gateway communi...

Страница 4: ...ement is ignored or overlooked the most reliable of instruments will be rendered useless A lot of effort has been made in preparing this instruction manual However the best of instruction manuals cann...

Страница 5: ...the weir is measured with the water level sensor ESM 12S uses a low range high precision pressure sensor for measuring this water head The pressure sensor is installed inside the slotted PVC pipe fix...

Страница 6: ...ccant unit and hydrophobic filter so that only dry air can enters the sensor vent line Desiccant and hydrophobic filter ensure that the air inside the moisture trap is dry Moisture content in air in t...

Страница 7: ...rectangular weir if ordered separately The weir comprising of stainless steel plate is provided in a suitable size and angle to suit expected flow rate The most used size is rectangular or 90 V notch...

Страница 8: ...ls and accessories are required for installation of the settlement monitoring system Impact or percussion electric drill with 8 mm and 6 mm drill bit for drilling in concrete or masonry for fixing fas...

Страница 9: ...ed inside it at its planned location as shown in figure below Following points needs attention while selecting the mounting location for seepage sensor 1 The distance of seepage sensor from V notch mu...

Страница 10: ...lient s scope from the measurement device in the direction of the flow 4 2 1 Points to be considered while installation of V notch and seepage sensor Use sealing compound to make junction box watertig...

Страница 11: ...junction box As described earlier moisture trap and junction box are supplied mounted on a wall mounting plate This assembly is installed near seepage sensor location Fix the wall mounting plate on a...

Страница 12: ...the monitoring room Depending on the distance from seepage sensor location to datalogger location a 3 core or 6 core cable will be used from junction box to datalogger The mounting detail for installi...

Страница 13: ...as 5 minutes Sensor cable can be directly terminated in the datalogger in case datalogger is installed near monitoring sensor In case the datalogger is installed at a distance control room from seepa...

Страница 14: ...30 datalogger is supplied with an interface card to connect Modbus RS 485 sensors For ESM 12S seepage monitoring systems Modbus option can be used in case datalogger is mounted at a distance more than...

Страница 15: ...configuration for model ESM 12S sensor with SDI 12 output is given below 1 Double click the ESDL 30 datalogger software icon on the Desktop The main screen of the application appears as displayed in f...

Страница 16: ...n choose Demo site for first time 5 Click on Config Sensors tab and the select Smart Config Sensor as shown in figure below 6 The screen as shown in figure 6 5 will appear Select channel number at whi...

Страница 17: ...eepage monitoring system Page 15 Figure 6 6 Smart config sensor screen 7 Screen as shown in figure 6 7 will appear Press Read button The application will fetch the information stored in the sensor as...

Страница 18: ...Page 16 Figure 6 8 ESM 12S sensor details 8 Press Monitor Sensor button The screen as shown in figure 6 9 will appear showing the values of settlement reading Parameter 1 and temperature reading param...

Страница 19: ...2 output is given below 1 Double click the ESDL 30 datalogger software icon on the Desktop The main screen of the application appears as displayed in figure below 2 Connecting Datalogger Click Datalog...

Страница 20: ...ation will display Open site window to select the site Select the required site from Select Site dropdown menu Click on Open button to open the site for Datalogger You can choose Demo site for first t...

Страница 21: ...nnel number at which the sensor is connected Select the sensor s address and click on Search button to find the sensor on SDI 12 Bus It will show the sensor details as shown in figure 6 15 Press on Op...

Страница 22: ...oring system Page 20 8 The application will fetch the information stored in the sensor as shown in figure 6 17 image 1 Pressing the green arrow one can check the parameter settings for all parameters...

Страница 23: ...Digital seepage monitoring system Page 21 9 Press Monitor Sensor button The screen as shown in figure 6 18 will appear showing the values of settlement reading Parameter 1 and temperature reading para...

Страница 24: ...r 7 3 Modbus details for connection to datalogger 7 3 1 Modbus RTU overview The Modbus RTU protocol uses packets messages made up of multiple sections to communicate and transfer data between devices...

Страница 25: ...s 16 bit Unsigned Integer 1 255 0x00DB Settling Time 2 bytes 16 bit Unsigned Integer 0 255 seconds 0x00DD Address of the Device 2 bytes 16 bit Unsigned Integer 0 247 0x00DE Baud Rate 4 bytes 32 bit Un...

Страница 26: ...egister value Parameter 32 bit Float 0 002460 06 Number of registers Lo bytes 00 00 Register value Ch 2 Status 16 bit un signed 05 Checksum CRC 41 DB E3 36 Register value Temperature 32 bit Float 27 4...

Страница 27: ...a microcontroller sensor module that reads the sensor a wireless communication module that transmits the digital data to the gateway and a processor that controls the two modules It is a highly relia...

Страница 28: ...output option The sensor with Modbus RS 485 output will be connected to the RS485 port center one of the digital node as shown in figure below Figure 10 3 Connection of digital sensor with Modbus RS 4...

Страница 29: ...ion Table Marking on Standard Tape mm Reading Observed by Automatic level sensor mm Error mm 0 0 00 0 10 200 00 200 10 0 25 400 00 400 25 0 25 600 00 600 25 0 15 800 00 800 15 0 25 1000 00 1000 25 0 1...

Страница 30: ...most reliable of instruments will be rendered useless The warranty is limited to as stated herein Encardio rite is not responsible for any consequential damages experienced by the user There are no ot...

Отзывы: