Version
Document Title
Release Date
01
WT 2.1
–
Owner’s Manual
2021-03-12
27
Appendix V.
Integration in Cabinets
In this appendix, technical information to allow safe and proper integration of cabinets using Enapter
water supply systems is given. At a minimum, the user/integrator must comply with the
manufacturer's instructions described hereafter and apply available industrial standards for system
safety.
The WT 2.1 is designed to allow simple installation of 19" racks and cabinets. By enabling each device
to share common connections, the integration is streamlined for quick and flexible installations. We
recommend using common lines to the left of the machines for the water connections ("H2O OUT")
and to create all necessary electrical and electronic ducting on the right of the devices. This method
allows individual devices to be pulled out of the cabinet without dismounting other devices'
connections. The lines should be offset from another, either vertically or horizontally, depending on
the integrator's space.
Cabinet
The front side of the cabinet housing the WT 2.1 must be accessible to manage all electrical and
mechanical connections and maintain the device. Enapter recommends installing the WT 2.1 into a
cabinet with a base of at least 600x800 mm to ease the design and integration of all associated piping,
systems, and safety components. The resulting cabinet must adhere to local safety rules and
regulations
–
ensure that the cabinet can be deployed and fixed safely.
Attention!
The integrator's responsibility is to ensure that all devices in the cabinet are
kept within operating limits. It may require active temperature/climate
control.
Contact Enapter support for help when starting a new integration project!