The tank has a conductivity sensor to measure the water quality in the inlet of the tank. If it is not
within limits required by Enapter systems, which is <20 µS/cm, the entry of water into the tank is
blocked until the sensor detects water with low conductivity again. At any rate, for a very short initial
time of the refilling, values up to 30 µS/cm are accepted to give time to the deionized water's source
to purify within the required values. In case of a warning, follow
to restore correct
functionality.
Thanks to a self-priming pump, the stored water is pumped towards the electrolysers: a check valve
is installed downstream of the pump to avoid backflow towards the water tank.
The pump has a pressure switch integrated, which controls the exiting fluid pressure (from port H2O
OUT): when the threshold (2.75 bar) is reached - when the User requires no water, the pressure
switch turns off the pump. The pressure value gained on the WT21 outlet pipe can be greater than
2.75 barg based on the water tank-electrolyser system's pressure drops.
When the pressure decreases lower than the threshold, the pump turns on again.
Three water levels will be monitored in the tank ("low", "medium", and "maximum") through a level
transmitter: the solenoid valve (N/C) closes when the maximum filling level is reached and opens
when the medium level is reached. During the first WT refilling, the water level is lower than the
minimum level, and the solenoid valve guarantees the water flows inside the tank.
The pump is powered only when the water level reaches the medium level, and it is powered OFF if
the tank empties up to the minimum level.
Suppose the power supply to the WT fails while the level has not reached the medium. In that case,
the pump will start working after restarting the system.
In normal operating conditions, the solenoid valve will allow the tank to be filled up to the maximum
level.
Suppose the power supply to the WT fails while the level has not reached the maximum. In that case,
the inlet valve will remain closed unless the medium level is not overtaken again after restarting the
system.
The 3 LEDs located next to the right handle on the front panel help indicate the
system status and operating condition. For more information on machine status and
operation conditions, the cloud services and Enapter app detail the specific device
states and error/warning messages. Please see the
.
For the Error Codes list and description, please visit the
.
9
https://handbook.enapter.com/electrolyser/wt21/wt21.html
10
https://handbook.enapter.com/electrolyser/wt21/wt21.html#warning-error-and-fatal-error-codes