The color of each zone indicates its status. See the descriptions in the following table:
The Zone Initialization Master Port field displays the port number of the port that is currently assigned as
the master for that particular zone. The Initialization Master is responsible for starting the change
notification process in each zone.
To add ports to a zone:
1.
Select the appropriate check boxes to place ports into zones.
2.
Click
Submit
.
To activate zoning:
1.
Select the
Zoning Active
check box near the bottom of the page.
2.
Click
Submit
.
To remove a port from a zone:
1.
Clear the appropriate check box.
2.
Click
Submit
.
To remove all ports from a zone:
1.
Click
Clear
at the end of the row of check boxes for the appropriate zone.
2.
Click
Submit
.
To remove all zones:
1.
Click
All
under the Clear Zone heading.
2.
Click
Submit
.
Color
Description
Down (red)
One or more ports have been selected, zoning has been activated, but
hardware has caused a failure.
Up (green)
Ports have been selected, zoning has been activated, and the FC-AL
circuit is operational.
Not Active (yellow)
Ports have been selected but zoning has not been activated.
Undefined (gray)
No ports have been selected.
Caution:
Clearing the Zoning Active check box will deactivate all zones, which may degrade