X.25 Configuration 7-19
6)
In the
Call Type
field, accept the default value
Permanent
or press
<Enter> to select
On-Demand
from the pop-up list.
Reminder: You must configure the X.25 Authentication
Options in the X.25 Profile if you select “on-
demand” as the Call Type.
On-Demand calls are established only when needed. The connections are
terminated whenever the link is void of network data. Termination is
determined by the Idle Line Time-out value. A connection failure is
retried only when more network data is directed to the remote
destination.
On-demand calls can be placed through either a specific interface or an
interface group, but not both.
−
You can display a list of Interface Group names by pressing <Enter>.
−
Select an X.25 interface group from the list, then press <Enter>.
Continue with Step 7 below.
OR
−
If an Interface Group name isn’t specified, select Interface Name,
then press <Enter> to display a list of X.25 interfaces.
The
Select Interface
pop-up window is displayed listing the
configured X.25 interfaces. This read-only list allows you to select
the name of the specific X.25 interface through which this WAN Call
Destination can be accessed.
−
Select an X.25 interface from the list, then press <Enter>.
Permanent
- calls can be placed only through a specific interface; they
cannot be directed to an interface group.
7)
Interface Name
: Press <Enter> and select an available Network
Interface from the pop-up list.
8)
In the
Circuit Type
field, accept the default value Switched Virtual
Circuit (SVC), or press <Enter
> to select Permanent Virtual Circuit
(PVC).
Содержание DCP_link
Страница 1: ...DCP_link Multi Protocol Router Advanced Configuration Guide PT1054605 00 Rev A December 1995...
Страница 11: ...Introduction Chapter 1 EMULEX DCP_LINK 1 2 HARDWARE REQUIREMENTS 1 3 SOFTWARE REQUIREMENTS 1 3...
Страница 18: ...2 4 Chapter 2 SW1 Base I O Address Settings Figure 2 1 SW1...
Страница 47: ...3 14 Chapter 3 X 21 Cable Assembly Figure 3 9 Emulex Part PT1011221 01...
Страница 50: ...Hardware Installation 3 17 RS 423 RS 485 Null Modem Cable Figure 3 12 Not Supplied by Emulex...
Страница 52: ...Hardware Installation 3 19 X 21 Null Modem Cable SHIELD Figure 3 14 Not Supplied by Emulex...