background image

27

FCC INTERFERENCE STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. (1) This 

device may not cause harmful interference, and (2) this device must accept any interference received, including 

interference that may cause undesired operation. 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of 

the FCC Rules. These limits are designed to provide reasonable protection against harmful Interference in a residential 

installation. 

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance 

with the instructions, may cause harmful interference to radio communications. 

However, there is no guarantee that interference will not occur in a particular installation If this equipment does cause 

harmful interference to radio or television reception, which can be determined by turning the equipment off and on, 

the user is encouraged to try to correct the interference by one of the following 

• 

Reorient or relocate the receiving antenna. 

• 

Increase the separation between the equipment and receiver 

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void 

the user’s authority to operate this equipment.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 

Radiation Exposure Statement:

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This 

equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

INDUSTRY CANADA COMPLIANT 

This device complies with RSS·210 of the Industry Canada Rules Operation Is subject to the following two conditions: 

(1) This device may not cause harmful interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation.

 

Radiation Exposure Statement:  

This equipment compiles with IC radiation exposure limits set forth for an uncontrolled environment. This equipment 

should be installed and operated with minimum distance 20cm between the radiator & your body. 

INDUSTRIE CANADA CONFORME

  

Ce dispositif est conforme à la norme CNR-210 d’industrie Canada applicable aux appareils radio exempts de licence. 

Son fonctionnement est sujet aux deux conditions suivantes: (1) le dispositif ne doit pas produire de brouillage 

préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu. y compris un brouillage susceptible de provoquer 

un fonctionnement indésirable. 

Déclaration d’exposition aux radiations: 

Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environnement non 

contrôle. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de 

rayonnement et votre corps.

Compliance

Содержание EMPowered in8-empwrunty

Страница 1: ...EMPoweredTM Motorized Touchscreen Works with Yale Access Keypad Smart Lock Deadbolt WORKS WITH ...

Страница 2: ...rews x4 8 x 3 4 Wood Screws x2 10 32 x 1 3 8 Machine Screws x2 10 x 3 Wood Screws Battery Cover Mounting Plate Security Plate Strike Plate AA x4 Batteries Connect Wi Fi Bridge DoorSense Interior Escutcheon Deadbolt Latch 2 3 8 Deadbolt Latch 2 3 4 ...

Страница 3: ...3 Door Prep Door Jamb Prep 2 3 8 or 2 3 4 Backset 2 1 8 Diameter Bore 1 8 Deep 2 1 4 1 1 Diameter Edge Bore 3 16 Deep 2 3 4 1 1 8 3 4 1 1 4 1 1 4 Deep ...

Страница 4: ...4 Install Latch Strike Plate 1 Note Use only the supplied latch for proper functionality Bolt must be in retracted unlocked position Note horizontal orientation of mechanism ...

Страница 5: ...5 Install Touchscreen Escutcheon 2 Outside of the door Inside of the door ...

Страница 6: ...6 Install Interior Mounting Plate 3 Loosen screw to remove cover ...

Страница 7: ...7 Connect the Cable Assembly 4 ...

Страница 8: ...8 Install Interior Escutcheon 5 See comment about reset button on page 26 Resetting Lock to Factory Default ...

Страница 9: ...9 Testing Operation 6 ...

Страница 10: ...10 1 Determine mounting location 1 1 2 3 1 2 DoorSenseTM Cover DoorSenseTM Housing Mounting Tape Mounting Screws Installing DoorSenseTM Surface Mount Option 7a ...

Страница 11: ...11 2 Attach mounting tape then screw into frame Installing DoorSenseTM Surface Mount Option 7a 3 Complete the DoorSense setup in the Yale Access app Lock Settings after completing step 12 ...

Страница 12: ...12 1 Remove magnet from housing and place DoorSenseTM Cap onto the magnet DoorSenseTM Housing DoorSenseTM Cap Installing DoorSenseTM Flush Mount Option 7b ...

Страница 13: ...3 2 Drill hole and Insert DoorSenseTM 3 1 2 5 8 Diameter 1 2 Deep 3 Complete the DoorSense setup in the Yale Access app Lock Settings after completing step 12 Installing DoorSenseTM Flush Mount Option 7b ...

Страница 14: ...14 Bolt must be in retracted unlocked position before installing batteries Install Batteries 8 ...

Страница 15: ...ng the lock to factory default Programming and use of lock is not possible until this step has been successfully completed Enter a 4 to 8 digit PIN Code followed by the gear key Registered Press Press Register Master PIN Code Press the gear key to continue Creating Master PIN Code 9 ...

Страница 16: ...16 Handing the Lock Activate the Lock OR Handing Lock Handing Lock Complete 10 ...

Страница 17: ...red back arrow Conversely you can wait for the menu to time out to exit the menu This completes the registration process for the module If the number 7 does not appear on the keypad it may be due to any of the following reasons 1 The Master PIN Code is not set 2 The module is not properly seating within the lock Press Press Enter Master PIN Code Press the gear key to continue Press 7 and then the ...

Страница 18: ... Yale August Connect Wi Fi Bridge 12 SET UP A DEVICE SET UP A DEVICE CAN T SCAN THE CODE CAN T SCAN THE CODE CAN T FIND THE SERIAL NUMBER ENTER SERIAL NUMBER FOUND ON CONNECT BRIDGE OR CAN T FIND THE SERIAL NUMBER EMTEK YALE RADIO MODULE ACCESSORY MD 01 CONNECT WI FI BRIDGE QR Codes Coming Soon QR Codes Coming Soon ...

Страница 19: ...19 Install Cover Secure cover by tightening screw on bottom 13 ...

Страница 20: ... Lock Response Menu mode enter number press key to continue 3 Enter digit corresponding to the function to be performed followed by the key Follow the voice commands The Master PIN Code must be registered prior to any other programming of the lock Feature Programming Through Menu Mode Using Master PIN Code ...

Страница 21: ...French Delete Continue Continue Continue Complete Complete Complete User PIN Code Registration Handing the Lock 1 1 1 1 2 2 1 1 3 3 3 3 3 PIN PIN PIN 2 5 Volume Settings 4 Language Setting Mode 5 Lockout Mode 6 Network Module Setting 7 Complete Disable Enable Enable Disable Disable 30 sec 60 sec 2 min 3 min Continue Advanced Lock Settings Automatic Re lock Inside Indicator Light One Touch Locking ...

Страница 22: ... the Low Battery Warning indicator flashes RED If battery power is completely lost use the 9 Volt battery override To use the 9V battery override apply 9V battery in either direction to terminals below the touchscreen for backup power option Wake up the lock and enter your PIN Code to unlock the door Master PIN Code The Master PIN Code is used for programing and for feature settings It must be cre...

Страница 23: ...alarm sounds if attempting to forcibly remove outside lock from door User PIN Code The User Code operates the lock Maximum number of User Codes is 250 with Network Module without Network Module maximum is 25 User Codes Note When deleting User Code s screen will display User Number not code being deleted Volume Setting Mode The volume setting for PIN Code verification is set to Low 2 by default oth...

Страница 24: ...t will not auto matically re lock Check to see if Auto Re lock Mode is enabled Disable Auto Re lock Mode to lock the door automatically If low battery indicator is lit see below change batteries PIN Codes will not register PIN Codes must consist of 4 to 8 digits to register The same PIN Code cannot be used for multiple users Registration management of PIN Codes is set by the authority of the Maste...

Страница 25: ...y made to bolt c Verify proper door preparation and re bore holes that are too small or misaligned d Verify keypad wire harness is routed under the bolt see Fig A e Verify bolt is installed with correct side up Fig A NOTE TO INSTALLER AND CONSUMER While EMTEK has included several features to prevent lockout 9V battery jumper low battery warnings it is still possible for a lockout situation to occu...

Страница 26: ...er programming of the lock When lock is reset to factory defaults all User Codes including the Master PIN Code are deleted and all programming features are reset to original default settings see below 1 Remove battery cover and batteries 2 Remove the interior escutcheon to access the reset button 3 The reset button see page 8 Step 5 is located beside the PCB cable connector 4 While pressing the re...

Страница 27: ...could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator your body ...

Страница 28: ...tate of California to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings ca gov Copyright 2021 EMTEK Products Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of EMTEK Products Inc is prohibited ...

Отзывы: