In case the battery is drained completely and the Battery

compartment is inside the safe, uncover the power terminals in the

front of the Entry Unit and power with fresh battery. Keep battery

pressed against the terminals until the safe is completely open.

This may require assistance of a second person.

Recycle the old battery.

Double signal for each key

Entry and lock electronics work correctly.

Long signal after any key

There may be a disturbance in the electronics.

What if…

… a user forgot her/his code?

With  help  of  the  main  code  you  can  delete  his/her  code  and  then  add  a  code  with  new

(known) numbers at the same position. The user can then change the numbers to his/her

new personal code.

… I want to remove the key option from a user code?

With help of the main code you can delete the user code and then add a code at the same

position without holding the key to the reader.  The user can change the code to the same

personal numbers he/she had before but is now not required to use a key additionally.

…I forgot the main code?

The  safe  can  be  opened  with  a  valid  secondary  opening  code;  however,  none  of  the

functions described in this manual will be available as they require entering the main code.

MAIN CODE

INSTRUCTIONS

I003

EN

170519

Electronic High Security Locks

Type HOME10

This instruction describes the lock features that are only accessible with the main code of

the lock (Factory Main Code: 1-2-3-4-5-6) if the lock is set-up for two or more secondary

codes.  For regular operation (open; close; change code; etc.) please refer to the user

instruction I002.

Make yourself familiar with the signals the lock emits.

Each key press is confirmed with an audio and light signal.

A double signal indicates that the last entry was valid

A long beep indicates that the last entry was invalid

Safety reference:

All codes are to be securely stored.  Do not use personal data (i.e. Birthdays, telephone numbers etc.)

as the code. Change the factory code before you start using the safe!

00 01 minutes de-activates Time Delay

© 2017 www.lock4safe.com

TIME DELAY

If time delay is active the waiting time begins after entry of one valid code. During that

period the light flashes at 2 second intervals. After expiration of the waiting time, the

lock emits short beeps every 2 seconds indicating that it awaits a valid code entry to

open the safe (open period).

Setting the Time Delay values

1. Can only be performed with the

Main Code

during open period!

2.

Press and hold

Key [9] until double signal.

The light remains ON during the following actions.

3. Enter Main Code.

4. Enter Delay period value, from 00 to 99 minutes i.e. five (5) min

5. Enter Open Period value, from 00 to 19 minutes, i.e. two (2) min

6. Confirm values (double signal).

RECEIVE AUDIT

The last 100 opening events are stored in your lock and can be retrieved by loading them

on a Dallas Key.

1.

Press and hold

Key [7] until double signal.

The light remains ON during the following actions.

2. Enter Main Code.

3. Plug suitable Dallas Key into the reader in the front of the Entry Unit.

4. When the download is completed the light turns off.

BATTERY

A series of signals indicates that the battery is weak and must be replaced.

Use only 9V ALKALINE or LITHIUM - batteries!

TEST ELECTRONICS

If you are in doubt that the lock works correctly, you can run the diagnostics

function.

1. Replace Battery with a fresh 9V ALKALINE Battery

2.

Press and hold

Key [5] until double signal.

The light remains ON during the following actions.

3. Enter Keys in exactly this sequence: [1], [2], [3], [4], [5], [6], [7], [8], [9], [0]