Additional Information
Using the LCD Display
The LCD Display will display the Following;
1. Forward And Reverse Power
2. VSWR
3. Time and Date (GMT or Local User Programmable see programming section)
4. Frequency Text (See programming section)
The user can scroll thru the above by pushing the select button on the front panel.
Resetting the Alarm
The Alarm can be reset two ways.
1. Pressing the alarm reset button on the front panel twice.
Note: If audible alarm is enabled this first
push of the button disables the audible alarm. If the user refrains from the second push the LCD
screen will return back to the alarm state.
2. Logging onto the web page and clicking the clear Alarm Submit button in the left frame.
In both cases a time and date stamp of how the alarm was cleared is written to the log.
Viewing the IP address
For security, the IP address can only be viewed on the LCD Display using the following procedure:
1. Remove DC power.
2. After the unit boots up and is displaying the Forward and Reverse Power (see Fig. 38)
3. Within 30 seconds hold down the Select Button.
4. While still holding down the select button the display will change to read “VSWR Readings” (Fig. 39)
5. Continue holding down the button until the IP Address is displayed (approximately 7 seconds)
6. Release the button and the IP address will scroll by twice.
7. The unit will then return to normal operation.
28
Fig. 38
Fig. 39