On the
Power Sensor Table
the User can Enter/Program the following;
Frequency:
Enter up to 8 characters of the the frequency.
Note: The Frequency text Box is used for user identification only, it can also be a name (i.e. Ch. 1).
Display:
Check the LCD check box to display the Power Sensor readings to the LCD Display Menu.
Check the HOME check box to display he Power Sensor readings on the Home page.
Alarm:
Click the “Y” radio button to activate the alarm, or the “N” radio button to disable the alarm.
Audible Alarm
:
Check this check box for an audible alarm to sound from the iPM-1.
Note: This check box is only displayed after Alarm check box = “Y” and has been submitted.
Continuous Transmitter:
Click the “Y” radio button if the unit is monitoring a Continuous Transmitter. This will allow an alarm on “0”
RF Forward Power.
Log RF Readings:
Click the “Y” radio button if logging of any change of RF Power is desired.
Click the “N” radio button to disable logging RF power with the exception of Auto PTT Test Readings.
High RF Power Alarm Set Point:
This value sets the High RF forward power alarm set point.
Hysteresis:
This value sets the sensitivity of a High RF Alarm. “0” being the lowest and “255” the highest.
Increase this number in small increments if High RF false alarms are experienced.
Low RF Power Alarm Set Point:
This value sets the Low RF forward power alarm set point.
Hysteresis: