![Empire VSM-18-1 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/empire/vsm-18-1/vsm-18-1_installation-instructions-and-owners-manual_2403762005.webp)
26284-3-0813
Page 5
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail warranty card supplied
with the fireplace.
3. Installer should show owner how to start and operate the
fireplace.
WARNING
ANY CHANGE TO THIS APPLIANCE OR ITS CONTROLS CAN
BE DANGEROUS.
Improper installation or use of the appliance can cause se-
rious injury or death from fire, burns, explosion or carbon
monoxide poisoning.
Figure 1
Product Components
• Burner Pan Assembly
— "M" model includes manual gas valve, regulator and safety
pilot.
— "R" model includes millivolt valve and safety thermopile
generator and on/off switch. A remote control or wall switch
accessory is available as an option for this model.
• 1 Bag of Glowing Embers (Rock Wool)
• 1 Damper Clamp
• 2 Bags Decorative Rock
Always consult your local Building Department regarding regula-
tions, codes or ordinances which apply to the installation of a vented
decorative gas log set in a solid-fuel burning fireplace.
This appliance is only for use with the type of gas indicated on the
rating plate.
This series is design certified in accordance with American National Standard/CSA Standard Z21.60 and CGA 2.26, respectively, by the
Canadian Standards Association as a Vented Decorative Appliance and should be installed according to these instructions.
Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on
the rating plate is the responsibility of the person and company making the change.
Important
All correspondence should refer to complete Model Number, Serial Number and type of gas.
Notice
:
During initial use of the logs and branches you will detect an odor as the logs and branches are cured.
INTRoducTIoN
GeNeRAl INFORMATION
specifications (Figure 1)
Model
Input
Btuh
** Reduced
Input
BTUH
Minimum
Front
Width
Depth Height
VSM-18* 65,000
40,000
32"
15"
22"
VSM-24* 75,000
50,000
34"
15"
22"
VSM-30* 75,000
60,000
38"
15"
22"
VSR-18† 65,000
40,000
28"
15"
22"
VSR-24† 75,000
50,000
30"
15"
22"
VSR-30† 75,000
60,000
34"
15"
22"
Model
Input
KW/H
**Reduced
Input BTUH
Minimum
Front
Width (cm)
Depth
(cm)
Height
(cm)
VSM-18*
19.0
11.7
81.3
38.1
55.8
VSM-24*
21.9
14.6
86.4
38.1
55.8
VSM-30*
21.9
17.5
96.5
38.1
55.8
VSR-18†
19.0
11.7
71.1
38.1
55.8
VSR-24†
21.9
14.6
76.2
38.1
55.8
VSR-30†
21.9
17.5
86.4
38.1
55.8
* M
Denotes manual gas valve
† R
Denotes millivolt gas valve
**
Attention: An additional main burner orifice is provided
in instruction package envelope to reduce the input of the burner
assembly.
Gas Inlet VSM Models
3/8" (9.5mm)
Gas Inlet VSR Models
3/8" (9.5mm)
Accessories for VsM and VsR Models
Embers Kit
EK-1
Accessories for VsR Models
Battery Operated Remote Control
FRBC
Electric Remote
FREC
Wall Switch
FWS