background image

26284-3-0813

Page 3

Installer: Please leave these instructions with the owner for future 

reference.

This unit complies with ANSI Z21.60and CGA 2.26 Decorative Gas 

Appliances For Installation In Solid Fuel Burning Fireplaces. Do not 

burn wood or solid fuels in a fireplace where a decorative gas log 

set is installed. This appliance is for installation only in a solid fuel 

burning fireplace, masonry fireplace or manufactured fireplace.

WARNING: 

Any modification to this gas log set or to controls 

can be dangerous. Improper installation or use of the gas log set 

can cause serious injury or death from fire, burns, explosion or 

carbon monoxide poisoning.

1.  Please follow all local codes regarding installation, combus-

tion and ventilation air or in the absence of local codes follow 

the National Fuel Gas Code ANSI Z223.1(U.S. installation), 

or CAN/CGA-B149, Installation Code (Canada installation).

2.  Proper installation, burner pan location and log placement is 

important to achieve optimum look and performance of your 

gas log set. The logs have been designed for easy location 

and placement on the grate and must be followed for proper 

operation.

3.  Do not operate this log set with glass doors in the closed 

position. A fireplace screen must be in place when the log 

set is burning. Adequate combustion air must be provided for 

proper venting. All flames should go up and out the top of the 

firebox into the flue vent. If any flames float or curl forward into 

the room 

do not operate appliance. 

Check for an open flue 

and adequate combustion air into the room. A damper clamp 

must be installed on the firebox damper to maintain an open 

flue vent condition.

4.  Young children must be carefully supervised when they are 

in the same room as the gas log while in operation. Do not 

place stockings, clothing or any flammable material above or 

near the fireplace.

5.  Do not substitute or use materials other than those supplied 

for use with the log set.

dO NOT OPeRATe THIs GAs lOG seT WITH GlAss dOORs ClOsed.

dANGER

: Indicates a hazardous situation which, if not 

avoided, will result in death or serious injury. 

WARNING

: Indicates a hazardous situation which, if 

not avoided, could result in death or serious injury.

cAuTIoN

: Indicates a hazardous situation which, if not 

avoided, could result in minor or moderate injury.

NOTICE

: Addresses practices not related to personal in-

jury.

  due to high temperatures the appliance should be located 

out of traffic and away from furniture and draperies.

•  Children and adults should be alerted to the hazards of 

high surface temperatures and should stay away to avoid 

burns or clothing ignition.

•  Young children should be carefully supervised when they 

are in the same room as the appliance.

•  Clothing or other flammable material should not be placed 

on or near the appliance.

• 

do not place trash or other articles on the log set during 

operation.

•  during manufacturing, fabricating and shipping, various 

components of this appliance are treated with certain oils, 

films or bonding agents. These bonding agents are not 

harmful but may produce annoying smoke and smells as 

they are burned off during initial operation of the appliance. 

This is a normal temporary occurrence. A window should 

be opened during the initial bake out period. 

•  Keep burner and control compartment clean. 
• 

WARNING: Before installing in a solid fuel burning 

fireplace, the chimney flue and firebox must be cleaned 

of soot, creosote, ashes and loose paint by a qualified 

chimney cleaner.

• 

WARNING: do not allow fans to blow directly into the 

fireplace.  Avoid  any  drafts  that  alter  burner  flame 

patterns.

• 

WARNING: do not use a blower insert, heat exchanger 

insert or other accessory not approved for use with this 

appliance.

•  Installation and repair should be done by a QuAlIFIEd 

seRVICe PeRsON. The appliance should be inspected 

before use and at least annually by a qualified service 

person. More frequent cleaning may be required due to 

excessive lint from carpeting, bedding materials, etc. It 

is  imperative  that  control  compartments,  burners  and 

circulating  air  passageways  of  the  appliance  be  kept 

clean.

•  dO NOT put anything around the fireplace that will obstruct 

the flow of ventilation air.

•  dO keep the appliance area clear and free from combustible 

material,  gasoline  and  other  flammable  vapors  and 

liquids.

•  A yearly examination and cleaning of the venting system 

of the solid-fuel burning fireplace must be performed by 

a qualified agency.

•  dO make a periodic visual check of pilot and burners. 

Clean and replace damaged parts.

•  dO NOT use this appliance if any part has been under 

water.  Immediately  call  a  qualified  service  technician 

to inspect the appliance and to replace any part of the 

control system and any gas control which has been under 

water. 

•  Ne pas se servir de cet appareil s'il a été plongé dans 

l'eau, complètement ou en partie. Appeler un technicien 

qualifié pour inspecter l'appareil et remplacer toute partie 

du système de contrôle et toute commande qui ont été 

plongés dans l'eau.

IMPORTANT sAFeTY INFORMATION

Содержание VSM-18-1

Страница 1: ...puis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qual ifié ou par le fournisseur de gaz AVERTISSEMENT Assurez vous de bien suivre les instructions données dans cette notice pour rédu ire au minimum le risque d incen...

Страница 2: ...ics 12 Wiring 13 Cleaning and Servicing 13 Troubleshooting 14 Parts List 15 Parts View 16 Propane LP Gas Conversion Instructions 17 Natural Gas Conversion Instructions 18 Master Parts Distributor List 19 How To Order Repair Parts 19 Warranty 20 CAUTION If logs or branches are damaged do not use A certain amount of sooting will occur which enhances the realistic look of the logs and branches If an ...

Страница 3: ...turestheapplianceshouldbelocated out of traffic and away from furniture and draperies Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room as the appliance Clothingorotherflammablematerialshouldnotbeplaced on or near the appliance Do not...

Страница 4: ...rm service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of newcylindersandtanks ispossible Therefore peopleshould be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinstalled old tanks if...

Страница 5: ... Decorative Appliance and should be installed according to these instructions Any alteration of the original design installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change Important All correspondence should refer to complete Model Number Serial Number and type of gas Notice During...

Страница 6: ...high altitude applications this appliance is suitable for installation at elevations between 0 feet 0m and 4 500 1 370m without change When installing this unit at an elevation above 4500 feet 1 370m in Canada check with local authorities Consult your local gas utility for assistance in determining the proper orifice for location Turn off gas supply to fireplace or firebox Have the fireplace floor...

Страница 7: ... 6 22 1 28 3 35 3 44 2 15 8 6 12 6 17 3 21 2 26 4 32 2 31 2 20 7 5 10 8 14 5 18 1 22 1 26 4 31 2 25 6 6 9 6 12 6 15 9 18 1 22 9 27 3 30 6 2 9 1 11 3 14 5 17 3 20 4 24 6 35 5 7 8 0 10 8 13 2 15 9 18 9 22 1 40 5 3 7 5 10 2 12 6 15 2 18 1 20 4 Appliance Input Rate KW HR 5 9 8 8 11 7 14 6 17 6 20 5 23 4 Chimney Height m Minimum Opening sq in 3 05 72 9 107 1 142 6 182 6 227 8 285 2 4 57 55 5 81 3 111 6...

Страница 8: ...lve a 1 8 3 175mm N P T pluggedtapping accessiblefortestgaugeconnection must be placed immediately upstream of the gas supply connection to the appliance 2 Theapplianceanditsindividualshutoffvalvemustbedisconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa 3 Theappliancemustbeisolatedfromthegassupplypipingsystem byc...

Страница 9: ...ate after 10 to 15 minutes the flame appearance should be sets of yellow flames NOTICE all flames will be random by design flame height will go up and down Avoid any drafts that alter burner flame patterns Do not allow fans to blow directly into fireplace Do not place a blower inside the burner area of the firebox Ceiling fans may create drafts that alter flame patterns Sooting and improper burnin...

Страница 10: ...Lighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for gas Be sure to smell ne...

Страница 11: ... This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in ...

Страница 12: ...pilot after the pilot orifice has been removed To Remove Pilot Orifice 1 Disconnect the pilot supply line at the pilot burner 2 Remove pilot orifice from pilot burner It may be necessary to tap on pilot burner in order to remove the pilot orifice Pilot Flame Pattern Figure 9 If pilot flame pattern is incorrect See Troubleshooting page 15 Main Burner Flame Pattern The main burner flame will be comp...

Страница 13: ... Check for gas leaks Remote Receiver VSR 18 24 30 Use the following steps to place the remote receiver adjacent to the gas valve Attention 1 The remote receiver can not be placed behind the gas valve and burner assembly 2 When facing the appliance the remote receiver must be placed in the right side firebox toward the front NOTICE Do not let remote control receiver come in contact with burner asse...

Страница 14: ...e Check all connections and try If still not operating disconnect lead between thermo couple switch and valve operator Then disconnect lead to pilot magnet and connect to valve operator terminal TP TH If pilot remains lit fault lies with thermocouple Check that bulb is in proper location If still not working replace thermocouple see drawing in manual for ad ditional information 3 Pilot burning no ...

Страница 15: ...2 R10408 GAS VALVE LPG 12 R10407 GAS VALVE NAT NS R1260 3 8 ELBOW 90 STREET NS R 5910 SWITCH LOG ASSEMBLY NS R 5699 WIRE HARNESS NS R 5757 ON OFF SWITCH NS 26282 TUBING VALVE TO PILOT NS 26283 TUBING VALVE TO BURNER NS 15496 ROCK WOOL NS 11788 DECORATIVE ROCK NS R 2809 DAMPER CLAMP NS R 734 LIGHTER ROD NS R 1054 THERMOPILE VSM 18 24 30 4 P 265 ORIFICE LPG 18 40 000 BTU 4 P 211 ORIFICE NAT 18 40 00...

Страница 16: ...26284 3 0813 Page 16 1 2 3 4 5 6 7 8 9 9 12 10 11 13 14 15 16 17 11 18 19 Parts view ...

Страница 17: ...or future use 9 Insert Propane LP gas pilot orifice marked 8 into pilot burner 10 Attach pilot tubing into pilot burner 11 Connect gas supply line to vented decorative log set 12 Attach R 1322 conversion label and R 1321 gas conversion label to the 4 3 4 x 7 1 4 metal plate supplied in conversion kit Attach 4 3 4 x 7 1 4 metal plate to metal chain which is attached to base assembly 13 Pressure Tes...

Страница 18: ...0 BTUH input 7 Remove pilot tubing from pilot burner 8 Remove Propane LP gas pilot orifice from pilot burner Save the Propane LP gas pilot orifice removed from the appliance for future use 9 Insert Natural gas pilot orifice marked 12 into pilot burner 10 Attach pilot tubing into pilot burner 11 Connect gas supply line to vented decorative log set 12 Attach R 1322 conversion label and R 1320 gas co...

Страница 19: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the fol lowing illustration and part list Be sure to give all this information Appliance Model Number Part Description Appliance Serial Nu...

Страница 20: ...wner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or payment record should be kept to verify purchase date and establish warranty period Ready access to the appliance for service What Is Not Covered Damages that might result from the use misuse or improper installation of this ...

Отзывы: